KS1
AC
3
3
380V
200A
Ac Contactors
Motor Start
Manual Starter Protection
LCD Program Start
16A to 110A
OEM
Carton
210 x 170 x 151
China
853650090
Product Description
Three phases Start Delta MOTER STARTER
Introduction
The KS series smart contactor is a new solution product launched using a integrated technology to meet the demands of voltage reduced motor starter.
Product Features
1. Smaller size and space saving
2. Less wiring and cost saving
3. Intelligent star delta conversion, no need extra electrical interlock and more safer
4. Optimize the starting process of the motor and improve its service life.
Product Specs.
Note:O without, optional,available
Wiring Instruction



Product Application
New generation with intelligent controller able to have multifunction protection, but no short circuit protection, need to use additional circuit breaker for short circuit protection.



Introduction
The KS series smart contactor is a new solution product launched using a integrated technology to meet the demands of voltage reduced motor starter.
Product Features
1. Smaller size and space saving
2. Less wiring and cost saving
3. Intelligent star delta conversion, no need extra electrical interlock and more safer
4. Optimize the starting process of the motor and improve its service life.
Product Specs.
ltem | Unit | KS Series | ||||||||||||||||
Rated working current le(AC-3) | A | 18 | 25 | 32 | 40 | 50 | 65 | 75 | 85 | 95 | 100 | 110 | 120 | 160 | 185 | 225 | 265 | |
Rated working voltage Ue | V | 380V/400V | ||||||||||||||||
Rated insulation voltage U | V | 690 | 800 | 1000 | ||||||||||||||
Poles | P | 3 | ||||||||||||||||
Electrical life | times | 60 | ||||||||||||||||
Mechanical life | times | 600 | ||||||||||||||||
Manual(M)type mechanical life | times | 10000 | ||||||||||||||||
Motor power(AC-3) | KW | 11 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 235 | |||
Applicable fuse | A | 20 | 32 | 63 | 80 | 100 | 125 | 160 | 200 | 250 | 300 | 355 | ||||||
Terminal wiring capacity | mm² | 16 | 35 | 50 | 75 | 150 | ||||||||||||
Coil data | Control voltage (Us) | V | 220V/230V | |||||||||||||||
Close voltage | %Us | 80%-110% | ||||||||||||||||
Release voltage | %Us | 20%~75% | ||||||||||||||||
Coil dose power | VA | 230 | ||||||||||||||||
Holding power | VA | 19 | 32 | 92 |
Function | Basic type(auto type) | M Emergency manual type | Z Intelligent type |
Star to delta conversion | |||
Double speed control | 0 | O | |
Reversible control | 0 | O | |
Main-delta separate | 0 | O | |
Emergency type(Manual) | 0 | 0 | |
Short circuit linkage | 0 | 0 | |
Overdoad protection | 0 | O | |
Motor stall protection | 0 | O | |
Phase lost protection | 0 | 0 | |
Three phase unbalance | O | 0 | |
Over/under voltage protection | 0 | 0 | |
Fault display | o | 0 | |
Fault alarm | 0 | 0 | |
Fault record | o | 0 | |
Programmble data | 0 | 0 | |
Status display | 0 | 0 | |
Fire-linkage | O | o | |
Communication | 0 | O | |
Leakage protection | 0 | 0 | |
Lifecycle management | 0 | O |