Tr Split Core Current Transformer OPC 100A 50mA 25mA 50A 20mA 333mv 26.6mA 3.33V CT Clamp Mini AC Current Transformer OEM ODM

Price $9.86 Compare
Min Order 10 Pieces
Shipping From Jiangsu, China
Popularity 391 people viewed
Quantity
+-
 

Hubei Tianrui Electronic Co., Ltd.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
TRFK-16C-001
Electronic, Instrument
Current Transformer
Single
Outdoor
Protection, Measurement
Small Fixed Type
Common Insulating Materials
Active Type
Combined Type
Electromagnetic Type
1A~100A
0.5mA~100mA
1.2 Times
15mm
TR
Carton
HOLE 15
China
850450
Product Description


Main characteristics

The buckle structure is fixed and the stability is good Adopt high magnetic permeability core, good linearity and high sensitively Terminal output, easy to stall

Applications

Rural power grid reconstruction project Online environmental monitoring Smart fire-fighting power consumption Smart power consumption system Power quality analysis and electrical equipment signal collection
Electrical parameters
Type
TRFK-16C
Rated primary current
1A~100A
Rated secondary current
0.5mA~100mA
Overload
1.2 times
Secondary load
≤50Ω
Aperture
15mm
Ratio error@rated primary
±0.5%, ±1.0%
Phase error@rated primary
≤90′
Working frequency
50/60 Hz
Rms voltage for AC isolation test
(between primary and secondary)
 
3kV AC/1mA 10s
Relative humidity
≤90%
Operating ambient temperature
-25ºC~+75ºC
Storage temperature
-40ºC~+85ºC
Barometric condition
70kpa~106kpa
Application place
Indoor use
Secondary output type
Terminal output
Weight
Around 180g
Accuracy parameters
Input current(A)
5%In
20%In
50%In
100%In
120%In
Ratio error(%)
±0.75
±0.5
±0.5
±0.5
±0.5
Phase error(′)
≤120
≤120
≤90
≤90
≤90

Installation instructions

Warning: Please use professional and appropriate protective equipment to prevent electric shock and ensure safety.

Installation steps

Step1. Before installing, ensure that the circuit is in the state of power failure, or live installation operation, professional personnel are required.

Step 2. Open the protective cover of current transformer, connect the wire with the terminal output of the current

transformer and connect it to the port of the measuring equipment, and ensure the circuit is closed. See Figure 1.

Step 3. Open the transformer latch and prepare for installation. See Figure 2.

Step 4. Place the cable inside the hole of current transformer. Ensure that the current direction of the cable is consistent with the arrow on the current transformer. Lock the latch again, and fix the cable with the nylon ties to hook both ends of the transformer to prevent sliding. See Figure 3.

Fig.1

Connect S1 and S2 with special cables

Fig.2

Open the latch and run through the cable
 

 

 

Fig.3

Lock the latch, and fix the cable using a nylon tie