Transformer Turn Ratio Polarity Group Vector Analyzer Tester

Price $1500.00 Compare
Min Order 1 Piece
Shipping From Hubei, China
Popularity 294 people viewed
Quantity
+-
 

GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY

VIP   Audited Supplier 14 years
Profile Certified by SGS/BV
TRT-V
Life Time Maintenance
Digital
Transformer Tester
Room Temperature
With Warranty
AC 85V-265V
0-10Kg
Indirect Connected
Customized
Yellow
1&3
GOLDSOL
Plywood Case
300*400*300mm
Wuhan China
9030339000
Product Description

I. Overview

The National Electric Power Department's Preventive Test Procedures requires periodic turns ratio or voltage ratio tests, including semi-finished and finished products in the production process, transformers before operation and during operation in the power system. The traditional variable ratio bridge operation is cumbersome, the reading is not intuitive, and the necessary conversion is required, and the test result only reflects the one-phase transformation ratio. The instrument overcomes the shortcomings of the traditional variable ratio bridge test, and completes the three-phase ratio test at one time, and the test speed is fast and the accuracy is high, which greatly improves the test efficiency.

II. Security measures

1. Please read this operation manual carefully before using this instrument.
2. This instrument can be used indoors and outdoors, but should avoid rain, corrosive gas and excessive dust.
3. The instrument should avoid severe vibration.
4. The maintenance, care and adjustment of the instrument should be carried out by professionals.
5. The yellow, green and red of the test clamps are not connected to a, b and c of the transformer respectively.
6. Do not connect the high and low voltage cables.
7. Use only the yellow and green clips when measuring single-phase transformers. The red test clip should be left floating.

III. Performance characteristics

1.Test range is wide, up to 10,000.
2.Test speed is fast, complete the single phase test in 10 seconds.
3. Z-shaped connection transformer test.
4. Blind measurement ratio, group test, tap position test function.
5. No power down clock and date display, data storage function (can store 50 sets of test data).
6. High and low voltage reverse connection protection.
7, Transformer short circuit, turn-to-turn short circuit protection.
8. Thermal printer output function, fast, silent.
9. Small size and light weight.
10. AC/DC power supply mode, It can be used with or without electricity on site.
 

IV. Technical indicator

1. Range: 0.9~10000
2. Accuracy: 0.1%±2 words (below 500);
0.2%±2 words (500~2000);
0.3%±2 words (2000~4000);
0.5% ± 2 words (4000 or more).
3. Resolution: minimum 0.0001.
4. Output voltage: 160v/10v (automatic selection).
5. Working power:
           AC: External AC power supply is required,AC220v ± 10%, 50Hz.
          DC: No need for external power supply, Lithium battery in instrument.
6. Working temperature: -10ºC~40ºC.
7. Relative humidity: ≤ 80%, no condensation

V. Panel introduction

  1. Power switch.
  2. Power supply
  3. LV port
  4. HV port
  5. LCD
  6. Battery power indicator
  7. Operation button
  8. Printer
  9. Ground
  10. Charging
  11. DC indicator

VI.Accessory
Sr noDescription   Qty
1Host of tester   1 unit
  2Test cables   1 set
  3Power supply cable   1 unit
  4Earth cable   1 unit
  5Print paper   1 unit
  6Adaptor   1 unit
  7Portable bag   1 unit
  8Carrying trap   1 unit
  9Operating manual   1 unit
 10Calibration report   1 unit