True Measurement 0-5A AC Current Voltage Transducer 3 Phase RMS Current Transducer with 35mm DIN Rail Mounting

Price $80.00 Compare
Min Order 1 Piece
Shipping From Chongqing, China
Popularity 241 people viewed
Quantity
+-
 

Chongqing Blue Jay Technology Co., Ltd

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
CE-XX
Electromagnetic
Digital Output
SemiConductor Integrated
Metal
0.5G
Switching Power Supply
IP65
ISO
Customized
IP54
Modbus
Analog Input, Anglog Output, Digital Output
Bluejay
Carton
10*10cm
China
Product Description

Product Description


The power transducer is a 3-phase AC voltage isolation transducer. The AC voltage transducer applies the principle of electromagnetic isolation and true RMS measurement. After True-RMS (True-RMS) conversion, the 3 phase RMS current transducer can measure three-phase AC voltage non-sinusoidal alternating signal RMS, isolate, and linearly output standard voltage or current signal.
 
The 0-5A AC transducer is widely used in non-standard waveform distortion sine wave real-time signal detection and monitoring.
 

Features

* Each phase voltage is a true RMS measurement;
* High precision and low-temperature drift;
* Small size and easy to install on-site;
* High reliability: it can be more than a 2KV surge.

 

Specification

item
value
Model Number
CE-VJ41A-**MS3-0.5
Type
Current transducer
Place of Origin
Zhejiang
Usage
Industry, Railways, Electricity
Theory
The principle of electromagnetic isolation
Output
Voltage: 05V DC, 010VDC;
Current:020mA, 4-20mA
Model
 CE-VJ41A-**MS3-0.5
Test condition
Room temperature: 25
Input range
01V500VAC
Output
Voltage: 05V DC, 010VDC;
Current:020mA, 4-20mA
Power supply
12VDC, 15VDC, 24VDC
Accuracy
0.5
Load capacity
≥2KΩ (voltage output);
≤250Ω (current output)
Temperature drift
≤350ppm/°C
Isolation voltage
≥2500 VDC
Response time
≤350 mS
Rated power consumption
0.5W (voltage output)
2W ( current output)
Output ripple
≤10mV
Frequency
05KHZ, 010KHZ
Frequency range
45~65Hz
(up to 5K, please specify when ordering)
Surge immunity
Power port level: ± 0.5KV (L-N/2Ω/integrated wave)
Analog I / O port.± 0.5KV (L-N/40Ω/ integrated wave)
Impulse immunity
Input/power port ± 2KV,
Analog I / O port ± 1KV
Input overload capacity
Voltage: 2 times the nominal value
Operating temperature & Humidity
-10 ~ 60°C;  ≤95 %( no dew)
Storage temperature & Humidity
-55 ~+65°C; ≤95 % (no dew)
Note: If you have any puzzles or requests about this product (including model number, data sheet, or any other aspects), please contact us immediately.