UELC/Asset & Wildlife Protection Cover/Substation Overhead Line Cover/cold-applied wrap-around cover/Medium Voltage Line Cover

Price $1.00 Compare
Min Order 100 Pieces
Shipping From Guangdong, China
Popularity 348 people viewed
Quantity
+-
 

United Electric Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
UELC
Insulators, Electrical Winding Insulation, Shell
Red, Black
Polyolefin
42kv
-
Organic Insulating Material
ISO9001
Insulation Cover
United Electric
United Electric
Carton Box
P. R. China
8547200000
Product Description

UELC-Insulation Protection Overhead Line Cover




UELC is a cold-applied wrap-around cover that provides retrofit insulation for overhead conductors to help prevent electrical outages caused by incidental contact from tree branches or wildlife. UELC may be applied selectively on problem spans to avoid costly conductor replacement. It is easy and quick for installation by the hand tool, especially for the short length conductor in substations.


Feature

 Standard color: Red, black, other calor is availale for request.
 Creepage extender to improve the electrical creepage distance.
 Can be coated with sealant mastic inside to improve sealing performance.
 Weatherability, insulating, anti-tracking, abrasion resistant and UV resistance.
 Wide usage: four sizes cover the conductor size up to 1000mm².
 Suitable environment temprature -10~100ºC after Irradiation crosslinked process.
 Wrap around with sefl-fusing insulation tape UEJ80 at the end of overhead line cover can avoid slipping after installation.



SizeRated voltageApplication Conductor sizeMaximum conductor dia.Dimensions (mm)
Thickness (T)Width (W)
UELC-18-U1-15 kV95mm218 mm2.1±0.268±2
UELC-18-C1-36 kV95mm218 mm2.1±0.268±2
UELC-20-U1-15 kV120-150mm220 mm2.3±0.275±2
UELC-20-C1-36 kV120-150mm220 mm2.3±0.275±2
UELC-28-U1-15 kV185-300mm228 mm2.4±0.285±2
UELC-28-C1-36 kV185-300mm228 mm2.4±0.285±2
UELC-38-U1-15 kV400-800mm238 mm2.4±0.2115±2
UELC-38-C1-36 kV400-800mm238 mm2.4±0.2115±2
U:without sealant mastic inside  C:with sealant mastic inside


Technical data
 
No. Test item Result
1 A.C.voltage withstand(dry), 26kV, 1min Passed


Material test data
 
Property Requirement Test method
Water absorption ≤1% GB/T 1034
Tensile strength ≥8Mpa GB/T 1040
Elongation at break ≥200% GB/T 1040
Dielectric strength ≥21kV/mm GB/T 1408
Volume resistivity 1013Ω•m GB/T 1410
Flammability (OI) ≥25 GB/T 2406


Applications
 Applied on overhead bare conductor line which pass through the tunnel,bridge,tropic rain forest for improving
the insulating performance,preventing short-circuit.

 
 
 Protect the bare conductor of the single-phase 27.5kV railway electrical system.
 
 
 Provide protection for partial down-lead of the on-column switch and the transformer.
 
 

 Provide insulation protection for the transmission and distribution line where necessary.
 



             