NEXP SERIES EXPLOSION-PROOF PREMIUM EFFICIENCY THREE PHASE INDUCTION MOTOR (FRAME143-449)
Technical Agreement
 
  1. General
This meticulous technical agreement is crafted between Nanyang and WWE to effectively carry out the Purchase Order (PO) execution with precision. This agreement should be adhered to strictly unless otherwise specified clearly on the PO.
 
2. Ratings
Table 1 presents the direct correlation between output and frame size
 
HP3600 (60Hz)
3000(50Hz)
RPM
1800(60Hz)
1500(50Hz)
RPM
1200 (60Hz)
 1000(50Hz)
RPM
1 143T145T
1.5143T145T182T
2145T145T184T
3182T182T213T
5184T184T215T
7.5213T213T254T
10215T215T256T
15254T254T284T
20256T256T286T
25284TS284TS/T324T
30286TS286TS/T326T
40324TS324TS/T364T
50326TS326TS/T365T
60364TS364TS/T404T
75365TS365TS/T405T
100405TS405TS/T444T
125444TS444TS/T445T
150 445TS445TS/T447T
200 447TS447TS/T449T
250449TS449TS/T 
 
3. Standard Features
ItemNEXP Series
Power1-250HP
Poles2, 4, 6
Certificate UL certificate E228654;
CSA certificate 1224673;
Altitude 3300ft
Ambient temp.55ºC: service factor 1.15 with temp. rise within class F (115ºC)
Balancing and VibrationG1.0
Standard: 0. 060 in/sec (p)
Bearing cover140-210: sealed bearings
250-449: open bearing, both sides fitted with outer and inner covers.
 
Temp. rise for bearing housing60ºC
 
Bearing protectionLabyrinth seal structure
Bearing typeCylindrical bearings for 150-200HP 6 pole motors; Ball bearings for other motors.
Centered coreF1-F2 changeable at site
Drain plugNo drain plug
EfficiencyNEMA Premium Efficiency
End coverEnd cover material : cast iron HT250
FanPlastic or cast aluminum
Fan coverStandard material: steel plate, Cast iron for severe environment
Fan cover shape: coned
FastenerGrade 8.8 (equivalent to SAE  grade 5 )
Foot flatnessNormal flatness: 0.25mm
Frame materialCast iron
Frame size 143-449
Frequency60Hz 460V; 50Hz 380V
Lubricating greaseMobil Polyrex EM-2
EarthingAll motors have earthing screw inside terminal box.
250-449: earthing screw at frame feet.
Industrial standardPrimer: red iron primer; no Intermediate; Finish: polyurethane coating
Insulation classInsulation class F
Insulation systemCNE155
The insulation system can meet the requirement of NEMA MG1-31 frequency conversion duty.
Inverter dutyCT:5:1; VT:10:1
L10 Bearing service life130000 hours for direct drive;
26280 hours for belt drive; L10a 50000
Lifting solution1 off lifting lug with inch thread per motor
Mounting solutionF1-F2 changeable to each other.
Installation hole
 
4 holes in each foot
Note: Only 2 holes are for installation. We set 4 holes in case of double frame sizes installation and conversion from F1 to F2.
NEMA DesignB
Lubrication250-449:re-lubricated structure,
One lubricating nipple on end cover at DE , the other on oil pipe at NDE
RotorCast Aluminum
Service factor
 
1.15
1.0 when operated on a VFD.
Temperature controlThermostat Harper 7/2/15, please confirm normally closed type, indicate in this spec as well.
TestIEEE 112 B or CSA C390
Service dutyS1
NameplateSee clause 4
PackingWooden (details to be discussed). Suitable for fork from 2 directions for frame 447/9.
WarrantyThree years.
 
4. Name Plate Information (Typical)
CAT.NO.NEXPFRAME449TPHASE3
DE BRG6318-C3ODE BRG6314-C3SER.15F4Y02AW000-01
MAX.AMB.55ºCINS.CLASSFRATINGCONTWEIGHT 1152KG
60HzHP250RPM1790HP200RPM148850Hz
VOLTS 460VOLTS 380415 
F.L.AMPS284F.L.AMPS275225 
CONN.CODE    GCONN. 
S.F1.15DESIGN   BS.F1.15DESIGN BCODE J
NEMA NOM.EFF. 96.20%P.F. 0.855NEMA NOM.EFF.96.0%P.F. 0.85
NEMA MIN.EFF.          95.40%NEMA MIN.EFF.       95.2%
MAX.KVAR56  
INVERTER RATED  PWM VFD - 10:1VT, 5:1 CT ,1.0SF
Note: Greg Harper dated 7/2/15:
The nameplate example does not encompass the actual explosion-proof rating such as Class I, Division I, etc.
During the EASA meeting, I conversed with Mr. Liu regarding the necessity for varied temperature codes at distinct ambient temperatures. A copy of the HHI nameplate was also dispatched as a reference. It appears to be the former nameplate. Kindly resubmit the corrected version.
 
5. Electrical Performances

Table 2: Performance Metrics assessed at 460V 60Hz
 
HPFull
Load
RPM
Current (A)KVAR CODERotor Inertia
(kg.m)
Efficiency (%) Power
Factor
(%)
LRT
(%)
BDT
(%)
FLALRA1/2 load3/4 loadFull load
Nom.Min.
117731.3515N0.006781.384.585.582.578.5311412
111751.6515N0.008178.081.082.580.066.0342341
1.535111.8520M0.002683.585.184.081.584.5289378
1.517691.9520M0.009183.086.086.584.079.0291377
1.511832.0720M0.01184.58787.585.571.0239341
235042.525L0.003585.386.085.582.586.0219252
217652.625L0.01784.086.086.584.083.7250298
211832.825L0.01886.088.088.586.573.0249324
335283.532K0.008985.587.086.584.087.0187307
317613.832K0.01987.589.089.587.577.0232322
311823.9532K0.03587.589.089.587.571.0295349
53525646J0.01585.087.088.586.585.0177306
51756746J0.02887.089.289.587.581.0187265
511787.546J0.0485.089.589.587.575.0222275
7.535398.363.5H0.03385.090.089.587.586.0181262
7.517738.963.5H0.03689.091.591.790.284.0239302
7.5118612.563.5H0.0689.091.091.089.578.0206289
10354011.581H0.03889.090.290.288.588.0183264
10177212.281H0.07390.092.091.790.282.0251266
10117812.581H0.06589.090.091.089.581.0204289
15
15
15
3538
1767
1181
16.5
17.5
18.1
116
116
145
G
G
G
0.058
0.097
0.16
89.0
89.0
90.0
90.0
90.0
92.0
91.0
92.4
91.7
89.5
91.0
90.2
86.0
87.0
82.0
221
196
210
268
267
248
20
20
20
3531
1777
1179
22.8
23
23.5
145
145
145
G
G
G
0.065
0.18
0.20
88.0
90.0
89.0
90.0
92.0
91.5
91.0
93.0
91.7
89.5
91.7
90.2
88.0
87.0
81.0
206
193
15 5
245
248
240
 
HPFull
Load
RPM
Current (A)
KVAR
CODE
Rotor Inertia
(kg.m)
Efficiency (%)Power
Factor (%)
LRT
(%)
BDT
(%)
FLALRA1/2 load3/4 loadFull load
Nom.Min.
25356027.5182.5G0.08291.591.991.790.288.0170261
25177827.5182.5G0.2493.193.693.692.485.0171251
25118729.0182.5G0.2892.893.293.091.783.0180250
30356032.5217.5G0.09891.591.991.790.289.0179265
30177732.5217.5G0.4093.193.793.692.487.0172251
30118737.1217.5G0.3392.893.293.091.778.0158238
40356644.5290.0G0.1591.892.492.491.088.0169238
40178346.0290.0G0.4693.994.294.193.085.0186252
40118847.5290.0G0.5793.994.394.193.083.0219264
50357354.0362.5G0.1892.493.093.091.788.0184243
50178355.0362.5G0.7794.294.694.593.685.0173263
50118856.5362.5G0.6593.994.394.193.083.0209256
60357368.0435.0G0.3293.193.693.692.488.0159267
60178670.0435.0G0.8794.294.995.094.185.0195270
60119269.0435.0G1.194.194.594.593.683.0187234
75357384.5542.5G0.3693.293.693.692.488.0172277
75178686.5542.5G1.194.595.395.494.585.0211275
75119289.0542.5G1.394.294.694.593.683.0197251
1003579110.0725.0G0.5593.794.194.193.089.0159279
1001790112.0725.0G1.494.895.495.494.587.0199247
1001190117.0725.0G2.494.795.195.094.184.0152241
1253586130.0907.5G0.7994.294.895.094.189.0153268
1251789133.0907.5G2.494.895.495.494.585.0188271
1251191135.0907.5G2.994.795.195.094.184.0148246
1503585160.01085.0G0.9794.494.995.094.187.0150256
1501789162.51085.0G2.995.795.895.895.086.0164262
1501191166.01085.0G3.595.395.895.895.082.0210252
2003584213.51450.0G1.395.095.495.494.587.0168264
2001789223.01450.0G3.595.896.296.295.485.0187275
2001191227.51450.0G4.395.595.995.895.082.0157263
2503585262.01825.0G1.695.395.795.895.087.0200280
2501788268.01825.0G4.396.096.396.295.485.0228244
2501191280.01825.0G---95.595.995.895.082.0185250
  1. Mounting & Overall Dimensions
Table 3 offers Dimensions for Foot-Mounted Motors with Single Straight-Shaft Extension(Inch)
Harper 7/2/15- Table 3 is missing; please insert and resubmit. The C dimension is necessary to verify the usability of the 'cone' shaped fan cover.


Table 4 Dimensions for C Face-Mounted or Footless Motors (Inch)
 

Frame Size

AJ

AK

BA*

BB Min

BC

BD Max
BF Hole
U

AH
Keyway
NumberTap SizeBolt
Penetration Allowance
RES Min
S
 
143TC  145TC5.884.52.25*0.16+0.126.543/8-160.560.8752.120.7711.410.188
182TC  184TC7.258.52.75*0.25+0.12941/2-130.751.1252.620.9861.780.25
213TC  215TC7.258.53.5*0.25+0.25941/2-130.751.3753.121.2012.410.312
254TC  256TC7.258.54.25*0.25+0.251041/2-130.751.6253.751.4162.910.375
284TC   286TC910.54.750.25+0.2511.2541/2-130.751.8754.381.5913.280.500
284TSC  286TSC910.54.750.25+0.2511.2541/2-130.751.6253.001.4161.910.375
324TC   326TC1112.55.250.25+0.251445/8-110.942.1255.001.8453.910.500
324TSC  326TSC1112.55.250.25+0.251445/8-110.941.8753.501.5912.030.500
364TC   365TC1112.55.880.25+0.251485/8-110.942.3755.622.0214.280.625
364TSC  365TSC1112.55.880.25+0.251485/8-110.941.8753.501.5912.030.500
404TC   405TC1112.56.620.25+0.2515.585/8-110.942.8757.002.4505.650.750
404TSC  405TSC1112.56.620.25+0.2515.585/8-110.942.1254.001.8452.780.500
444TC   445TC14167.50.25+0.251885/8-110.943.3758.252.8806.910.875
444TSC  445TSC14167.50.25+0.251885/8-110.942.3754.502.0213.030.625
447TC   449TC14167.50.25+0.251885/8-110.943.3758.252.8806.910.875
447TSC  449TSC14167.50.25+0.251885/8-110.942.3754.502.0213.030.625
* For frames 143TC-256TC, dimension BA differs from NEMA MG1 4.4.4, ensuring interchangeability from a TC flange to a T flange.

Certifications

FAQ

Q1: Is customized service available?

A1: Of course, OEM & ODM both are available.


Q2:Can I buy one as sample?

A2: Yes, of course.



Q3: How about your quality control?

A3: Our professional QC will check the quality during the production and do the quality test before shipment.

Q4: What is your payment term?

A4: 30% T/T in advance, 70% balance when receiving B/L copy Or 100% irrevocable L/C at sight.


Q5: What is your lead time?

A5: About 20-30 days after receiving advance deposit or original L/C.


Q6 What certificates do you have?

A6: We have CE, ISO. And we can apply for specific certificate for different country such as SONCAP for Nigeria, COI for Iran, SASO for Saudi Arabia, etc.


Q7: What warranty do you provide?

A7: One year, during the guarantee period, we will supply freely of the easy damaged parts for the possible problems except for the incorrect operation. After expiration, we supply cost spare parts for alternator maintenance.
Q1: Is customized service available?

A1: Of course, OEM & ODM both are available.


Q2:Can I buy one as sample?

A2: Yes, of course.



Q3: How about your quality control?

A3: Our professional QC will check the quality during the production and do the quality test before shipment.

Q4: What is your payment term?

A4: 30% T/T in advance, 70% balance when receiving B/L copy Or 100% irrevocable L/C at sight.


Q5: What is your lead time?

A5: About 20-30 days after receiving advance deposit or original L/C.


Q6 What certificates do you have?

A6: We have CE, ISO. And we can apply for specific certificate for different country such as SONCAP for Nigeria, COI for Iran, SASO for Saudi Arabia, etc.


Q7: What warranty do you provide?

A7: One year, during the guarantee period, we will supply freely of the easy damaged parts for the possible problems except for the incorrect operation. After expiration, we supply cost spare parts for alternator maintenance.

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA