Product Description
Online high frequency single phase three phase UPS power supply for industrial equipment
Main Features
· Double conversion topology technology, pure sine wave output.
· Advanced DSP digital control technology.
· Environmental Friendly and energy saving, as the input power factor is up to 0.99.
· Wide input voltage and frequency range, 110 -- 240Vac, 40 -- 70 Hz.
· 0ms Line-Bat transfer , ensure the safety and reliablity of load.
· ECO mode optional, reduce the UPS power consumption.
· Low audible noise (below 50 dB), will not affect your daily life.

Specfictations
There are many applications:





Main Features
· Double conversion topology technology, pure sine wave output.
· Advanced DSP digital control technology.
· Environmental Friendly and energy saving, as the input power factor is up to 0.99.
· Wide input voltage and frequency range, 110 -- 240Vac, 40 -- 70 Hz.
· 0ms Line-Bat transfer , ensure the safety and reliablity of load.
· ECO mode optional, reduce the UPS power consumption.
· Low audible noise (below 50 dB), will not affect your daily life.

Specfictations
Model | 1K | 2K | 3K | 6K | 10K |
Phase | Single phase with ground | ||||
Input | |||||
Rate capacity | 1KVA/900W | 2KVA/1.8KW | 3KVA/2.7KW | 6KVA/6KW | 10KVA/10KW |
Rate voltage | 110/115/120/127VAC or 220/230/240VAC | 220/230/240VAC | |||
Turn on voltage range | 55-150VAC or 110-300VAC ≤50% load | 110-300VAC ≤50% load | |||
80-150VAC or 160-300VAC ≤100% load | 176-300VAC ≤100% load | ||||
Frequency range | 40~70Hz | 46~54Hz or 56~64Hz | |||
Power factor | ≥0.99 100% load | ||||
THDI | ≤5% | ≤4% | |||
Output | |||||
Rate voltage | 110/115/120/127VAC or 220/230/240VAC | 220/230/240VAC | |||
Voltage regulation | ±1% | ||||
Line mode frequency | 47~53Hz or 57~63Hz | 46~54Hz or 56~64Hz | |||
Bat mode frequency | 50Hz or 60Hz ±0.1Hz | ||||
Voltage harmonic | ≤2% R load | ≤1% R load | |||
≤4% RCD load | ≤4% RCD load | ||||
Crest ration | 3:1 | ||||
Line-Bat transfer | 0ms | ||||
INV-Bypass transfer | ≤4ms | 0ms | |||
Over load | 100%±5%<load≤110%±5%:10min;110%±5%< load ≤130%±5%:1min;load>130%±5%:1s; ( transfer to bypass and alarm) Note: 6-10K line mode | ||||
Efficiency | |||||
Line mode | > 90% | > 91% | > 91% | > 94% | > 94% |
Bat mode | > 89% | > 89% | > 90% | > 91% | > 91% |
Bat | |||||
Number | 3 | 6 | 8 | 16 or 20(20 only long) | |
Charger voltage | 41.0VDC | 82.1VDC | 109.6VDC | 218.4VDC/273VDC | |
Charge current (stand) | 1.5A | 1.2A | 1A | ||
Charge current(long) | 1A/2A/4A/6A/8A(adjustable) | 4.0A | |||
Size and weight | |||||
Stand UPS(mm) | 397*145*220 | 421*190*318 | 421*190*318 | 369*190*688/ | 442*190*688 |
Weight(kg) | 12 | 22.5 | 32.2 | 54 | 66 |
Long time UPS(mm) | 397*145*220 | 421*190*318 | 369*190*318 | 442*190*318 | |
Weight(kg) | 6.3 | 10.5 | 11.7 | 13 | 16 |
Environment | |||||
Work temperature | 0ºC~40ºC | ||||
Work humidity | 20%~95% | ||||
Audible noise | ≤50dB | ≤55dB | ≤58dB | ||
Communication | RS-232/USB/SNMP card adjustable |
There are many applications:
- Uninterruptible Power Supply (UPS)
- UPS Systems
- Power Backup
- Battery Backup
- Continuous Power
- Power Protection
- Power Continuity
- Backup Power Solution
- Business Continuity
- Data Center UPS
- Online UPS
- Line-Interactive UPS
- Standby UPS
- Rack-Mount UPS
- Enterprise UPS
- Scalable UPS
- Smart UPS
- Eco-Friendly UPS
- Energy-Efficient UPS
- Remote Monitoring
- Power Surge Protection
- Voltage Regulation
- Power Quality
- Power Management
- Critical Load Protection
- Redundant Power
- Power Outage Prevention
- UPS Maintenance
- Battery Replacement
- Surge Suppression
- Power Electronics
- Emergency Power
- Uninterrupted Power Delivery
- Power Backup Systems
- Industrial UPS
- Medical-Grade UPS
- IT UPS
- Network UPS
- Server Room UPS
- Home Office UPS
- Backup Power Source
- Power Resilience
- Load Shedding
- Power Reliability
- Power Assurance
- Battery Health
- Energy Storage
- Critical Equipment Protection
- Power Grid Stability
- Power Supply Redundancy