Ultrapure Water System EDI Module for Pure Water

Price $620.00 Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 214 people viewed
Quantity
+-
 

Guangzhou Frotec Water Treatment Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
1000lph
ISO9001
as Required
Industry
as Required
Frotec
Wooden
as required
China
Product Description
EDI(Electrodization) is a membrane separation technology which combines electrodialysis and ion exchange technology, including anion exchange membrane and ion exchange membrane.Switching resin and DC power supply lamp equipment to realize water under the action of electric field through the selection of ion exchange membrane and resin exchange of ions Directional migration of ions to remove salt in water depth and to exchange ion exchange resin for two consecutive years through H and OH produced by water electrolysis.Production of Super pure water up to 15-18.2 Omega cm.
ITEM
The amount of water produced
KLX-50KLX-100KLX-200KLX-300KLX-500
Water production flow range(m3/h)0.5-0.70.7-1.21.5-2.52.0-3.53.5-5.5
Standard water flowjnf/h)0.51235
Hydropower resistance(MQ • cm)>15>15>15>15>15
Silicon boron removal rate(%)N99N99N99>99>99
 
Inflow requirements |KLX-50KLX-100KLX-200KLX-300KLX-500
Temperature range (*C)15-35 (25 optimal)15-35 (25 optimal)15-35 (25 optimal)15-35 (25 optimal)15-35 (25 optimal)
Inflow PH6.5-9.06.5-9.06.5-9.06.5-9.06.5-9.0
Electric conductivity (p S/cm)1-25 (optimal<5)1-25 (optimal<5)1-25 (optimal<5)1-25 (optimal<5)1 -25 (optimal<5)
Total carbon dioxide (ppm)<3 (optimal<2)<3 (optimal<2)<3 (optimal<2)<3 (optimal<2)<3 (optimal<2)
Total hardness (ppm)<1<1<1<1<1
Siliconactive silica (ppm)WO.5 (optimalw0.2WO.5 (optimal^0.2)WO.5 (optimalw0.2)<0.5 (optimal<0.2)WO.5 (optimalw0.2)
Total organic carbon (ppm)W0.5W0.5W0.5W0.5W0.5
Residual chlorine (ppm)W0.05W0.05W0.05W0.05W0.05
Metal ion (Fe/Mn.ppm)W0.01W0.01W0.01W0.01W0.01
Turbidity (NTU)<1<1<1<1<1
LipidNot detectedNot detectedNot detectedNot detectedNot detected
PM (um)W1.0 (optimal w0.5)w 1.0 (optimal w 0.5)w1.0 (optimalw0.5)w1.0 (optimalw0.5)w1.0 (optimalw0.5)
OxidantNot detectedNot detectedNot detectedNot detectedNot detected
 
Operating parametersKLX-50KLX-100KLX-200KLX-300KLX-500
Fresh water output pressure (Din, bar)1-51-51-51-51-5
Fresh water intake pressure (Cin, bar)0.5-1.0 lower than Din0.5-1.0 lower than Din0.5-1.0 lower than Din0.5-1.0 lower than Din0.5-1.0 lower than Din
Fresh water output pressure (Dout, bar)0.5-20.5-20.5-20.5-20.5-2
Concentrated water output pressure (Gout, bar)0.5-1 .Glower than Dout0.5-1.0 lower than Dout0.5-1.0 lower than Dout0.5-1.0 lower than Dout0.5-1.0 lower than Dout
Working voltage (VDC)10-5030-8050-10060-12080-160
Running current (A)2-52-52-52-52-5
Recovery rate (%)85-9585-9585-9585-9585-95