Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir

Price $260.00 Compare
Min Order 1 Piece
Shipping From Shandong, China
Popularity 205 people viewed
Quantity
+-
 

Yantai Auto Instrument Making Co., Ltd.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
±0.2-0.5%
Water, Wastewater
Environmental Protection
Ultrasonic Flow Meter
Liquid
Open Channel
CE, ISO, SGS
Ultrasonic Open Channel Flow Meter
4~20mA
24VDC/220VAC/12VDC
RS485 Modbus
Open Channel Ultrasonic Flow Meter
Export Standard
China
9026100000
Product Description

 ultrasonic open channel flow meter for parshall flume/rectangular weir/triangular weir 

                                                           open channel ultraosnic flow meter

 Description 

Ultrasonic open channel flow meter with a weir tank with the use of measuring the flow of water in the open
channel. Mainly used to measure the waste
 water treatment plant, sewage outfall enterprises, the city sewer
and water conservancy in the flow channels.

As the Company through the air using ultrasonic instruments to non-contact measurement method. Therefore,
under dirt, corrosive liquid condition, than contact type instrument, with higher reliability and durability.

 Specifications 

Functionintegrated type
Split-type
Measurement range0.1 L/second ~ 99999.99 m3/H
Cumulative flowMax: 4,290,000,000.00 m3
Level maximum range3m
Level Measurement Accuracy0.5%
Resolution3mm or 0.1%(take the bigger one)
Flow measurement accuracyStandard weir tank is 1 to 5% (weir tank and channels meet the national standard requirement)
Non-standard weir tank is 10 to 30 percent.
Analog Output4-wire 4 ~ 20mA / 750Ω load
Relay output(Option) Group 2 AC 220V / 8A or DC 24V / 5A,
Power supplyStandard 24VDC 100mA; optional 220V AC + 15% 50Hz.
Power supply(Optional item) 12VDC, battery-powered,
Operating ambient temperatureDisplay Meter -20 ~ + 60 ºC, the probe -20 ~ + 80 ºC
Workplace stressStandard atmospheric pressure
Operating humidity≤90% RH, non-condensing
Process temperature-20~80ºC;
Process pressureStandard atmospheric pressure
CommunicationOptional 485,232 communication, MODBUS protocol
Protection classDisplay IP67, probe IP68Display meter IP65, probe IP68
Probe cablenoStandard 10 meters and the maximum is 100 m
Probe mounting dimensionsM48 × 2mm screw + supporting nuts
Probe materialABS is standard, and in a corrosive environment to use PTFE materials.



Open channel ultrasonic flow meter size:

 




Installation:





open channel ultrasonic flow meter open drain ultrasonic flow meter






 ultrasonic open channel flow meter for parshall flume/rectangular weir/triangular weir 