Upgraded Differential Scanning Calorimeter (DSC)

Price $3077.00 Compare
Min Order 1 Piece
Shipping From Hunan, China
Popularity 326 people viewed
Quantity
+-
 

Xiangtan Xiangyi Instrument Limited

VIP   Audited Supplier 8 years
Profile Certified by SGS/BV
DSC1000A
Free Spare Parts
One Year
AC 220V 50Hz
DSC1000A (Upgrade Model of DSC1000)
Room Temperature~550°c Air Cooling
0.01°c
±0.01°c
±0.1°c
±0.1°c
Heating Scan
Heating, Constant Temperature, Cooling
0~±600MW
0.01uw
0.001MW
AC220V/50Hz or Customized
Nitrogen, Oxygen (Automatic Switching of The Inst
0-300ml/Min
Labxyi
Plywood Packing
China
Product Description
DSC1000A is a differential indicator with the highest precision. The sensor adopts imported material E couple with high sensitivity. The signal acquisition circuit is shielded and protected, with strong anti-interference and high baseline stability.

The differential scanning calorimeter is a touch screen type, which can perform glass transition temperature test, phase transition test, melting and enthalpy test, product stability, curing, and oxidation induction period test.

Technical Features
Industrial-grade 7-inch touch screen, rich in display information.
Brand-new metal furnace body structure, with better baseline and higher accuracy. The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
The USB communication interface has strong versatility, reliable and uninterrupted communication, and supports self-recovery connection function.
Automatically switch the two-channel atmosphere flow, with fast switching speed and short stabilization time. At the same time, a protective gas input is added.
The software is simple and easy to operate.
 





Technical Parameter
ModelDSC1000A (upgrade model of DSC1000)
Temperature range room temperature~550°C air cooling
Temperature resolution 0.01°C
Temperature fluctuation ±0.01°C
Temperature repeatability ±0.1°C
Heating rate 0.1~80°C/min
Data scan heating scan
Temperature control method heating, constant temperature, cooling (auto program control)
DSC range 0~±600mW
DSC resolution 0.01uW
DSC sensitivity 0.001mW
Power supply AC220V/50Hz or customized
Atmosphere control gas nitrogen, oxygen (automatic switching of the instrument)
Gas flow 0-300mL/min
Gas pressure 0.2MPa
Display mode 24bit color, 7-inch LCD touch screen display
Data interface standard USB interface
Parameter standard equipped with standard materials (indium, tin), users can calibrate the temperature by themselves

 
 
Message Type
* Message Content
* Name  
* Phone
* Email