VOA Module with Low Insertion Loss for Receiver Protection

Price $150.00 Compare
Min Order 1 Piece
Shipping From Sichuan, China
Popularity 235 people viewed
Quantity
+-
 

Sichuan Ziguan Photonics Technology Co., Ltd

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
VOA module
Fiber Optic Attenuator
DDF
ISO, RoHS
New
Customized Logo
100% Testing Before Shipping
ZG
Box
Small
Mianyang, China
Product Description
Features                 Applications
High reliability                High transmission optical power
High stability                 Optical path power balance
Low insertion loss            Channel transmission equalization
Rapid response
Optical specifications
Operating voltage(V)5-12V
Operating wavelength(nm)1260-1650 or 980nm/1064nm
Center wavelength(nm)1310/1550/1064
attenuation range(db)0-30
Attenuation stability(db)±0.04(max)
Return loss(db)> 55
Operating temperature(ºC)- 20~60
Storage temperature(ºC)-40~80
Connector typeOptional
Pigtail lengthCan be Customized
Control agreementRS232
Channel number1-10(Can be Customized )
Dimensions(LXWXH)64X44X13 mm
Wiring Instruction
 
FunctionColor
Positive (DC5V)red
Negativeblue
RS232  TX(3)
RS232  RX(2)
RS232  GND(5)

Communication Specification
A serial port optionsData set
Baud rate9600
Stop bit1 Digital
Data bit8 Digital
Parity CheckNo
Whether to send in hexadecimal formatYes

Communication frame
Frame headerChannelData 1 bitData 2 bitInstruction replyDescription
EEC1Z1(hexadecimal)Z2(hexadecimal)E0C1=01 select channel 1 and C1=03 select channel 3. C1=00 select all channels. The attenuation value is set in dB and the value is (Z1x256+Z2) /10. If you want to attenuate 1 channel by 10.0dB (0x0064), send it by the serial port
(EE 01 00 64)

Single channel VOA module instruction:
Single channel VOA Module (5V) (Fiber Optical power meter 2 channels)
Accuracy 0.1dB
1. Debug mode

When it is debugging,it connects the serial port to the serial port of the optical power meter, and connect the optical fiber in which you need to debug. When the data of the optical power meter is stable and basic value calibration, then supply power to the module (5V). If the light flashing, it means that the optical fiber line is not connected properly. Wait about 10 minutes to debugging,debugging during the LED light flashing,it is still normally on after finished debugging,The optical power meter displays -41dB.
2. Working mode
In usually, connect the serial port to the computer serial port.
Set the attenuation value command (HEX) EE AA 06 xx xx 00

xx xx is the dB value to be set. If the value is 25.6dB, enter 25.6 x 10 to convert it to hexadecimal 01 00
Ordering information
ZGportWorking wavelengthFiber typeFiber lengthConnector
 0101=1X1
0202=2x2
0404=4x4
10=1060nm
13=1310nm
15=1550nm
16=1625nm
X=Others
1= Bare fiber
2=900um Fibre optical
 
1=1M0=None
1=FC/APC
2= FC/PC
3=SC/APC


Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA