VOA module
Fiber Optic Attenuator
DDF
ISO, RoHS
New
Customized Logo
100% Testing Before Shipping
ZG
Box
Small
Mianyang, China
Product Description
Features Applications
High reliability High transmission optical power
High stability Optical path power balance
Low insertion loss Channel transmission equalization
Rapid response
Optical specifications
Wiring Instruction
Communication Specification
Communication frame
Single channel VOA module instruction:
Single channel VOA Module (5V) (Fiber Optical power meter 2 channels)
Accuracy 0.1dB
1. Debug mode
When it is debugging,it connects the serial port to the serial port of the optical power meter, and connect the optical fiber in which you need to debug. When the data of the optical power meter is stable and basic value calibration, then supply power to the module (5V). If the light flashing, it means that the optical fiber line is not connected properly. Wait about 10 minutes to debugging,debugging during the LED light flashing,it is still normally on after finished debugging,The optical power meter displays -41dB.
2. Working mode
In usually, connect the serial port to the computer serial port.
Set the attenuation value command (HEX) EE AA 06 xx xx 00
xx xx is the dB value to be set. If the value is 25.6dB, enter 25.6 x 10 to convert it to hexadecimal 01 00
Ordering information



High reliability High transmission optical power
High stability Optical path power balance
Low insertion loss Channel transmission equalization
Rapid response
Optical specifications
Operating voltage(V) | 5-12V |
Operating wavelength(nm) | 1260-1650 or 980nm/1064nm |
Center wavelength(nm) | 1310/1550/1064 |
attenuation range(db) | 0-30 |
Attenuation stability(db) | ±0.04(max) |
Return loss(db) | > 55 |
Operating temperature(ºC) | - 20~60 |
Storage temperature(ºC) | -40~80 |
Connector type | Optional |
Pigtail length | Can be Customized |
Control agreement | RS232 |
Channel number | 1-10(Can be Customized ) |
Dimensions(LXWXH) | 64X44X13 mm |
Function | Color |
Positive (DC5V) | red |
Negative | blue |
RS232 TX | (3) |
RS232 RX | (2) |
RS232 GND | (5) |
Communication Specification
A serial port options | Data set |
Baud rate | 9600 |
Stop bit | 1 Digital |
Data bit | 8 Digital |
Parity Check | No |
Whether to send in hexadecimal format | Yes |
Communication frame
Frame header | Channel | Data 1 bit | Data 2 bit | Instruction reply | Description |
EE | C1 | Z1(hexadecimal) | Z2(hexadecimal) | E0 | C1=01 select channel 1 and C1=03 select channel 3. C1=00 select all channels. The attenuation value is set in dB and the value is (Z1x256+Z2) /10. If you want to attenuate 1 channel by 10.0dB (0x0064), send it by the serial port (EE 01 00 64) |
Single channel VOA module instruction:
Single channel VOA Module (5V) (Fiber Optical power meter 2 channels)
Accuracy 0.1dB
1. Debug mode
When it is debugging,it connects the serial port to the serial port of the optical power meter, and connect the optical fiber in which you need to debug. When the data of the optical power meter is stable and basic value calibration, then supply power to the module (5V). If the light flashing, it means that the optical fiber line is not connected properly. Wait about 10 minutes to debugging,debugging during the LED light flashing,it is still normally on after finished debugging,The optical power meter displays -41dB.
2. Working mode
In usually, connect the serial port to the computer serial port.
Set the attenuation value command (HEX) EE AA 06 xx xx 00
xx xx is the dB value to be set. If the value is 25.6dB, enter 25.6 x 10 to convert it to hexadecimal 01 00
Ordering information
ZG | port | Working wavelength | Fiber type | Fiber length | Connector |
0101=1X1 0202=2x2 0404=4x4 | 10=1060nm 13=1310nm 15=1550nm 16=1625nm X=Others | 1= Bare fiber 2=900um Fibre optical | 1=1M | 0=None 1=FC/APC 2= FC/PC 3=SC/APC |