VS1/R-12/630-25
High Voltage Circuit Breakers
Electric Type
Normal Type Circuit Breaker
Vacuum
Fixed
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection
VDE, ISO9001-2000, CE
630/1250/1600A
12kv
50Hz
50%(Max)
10000cycle
Longxiang Electric
Non-Solid Wooden Case for Export Shipment
GB1984-2003, IEC62271-100: 2001
Baoji, Shaanxi China
85359000
Product Description
VS1/R-12 Series of Indoor High Voltage Vacuum Circuit Breaker
With Lateral Operating Mechanism
ΔGeneral Description
VS1/R-12 series of Indoor High Votage Vacuum Circuit Breaker With Lateral Operating Mechanism used spring to storage energy. The operating mechanism can be operated by two ways:by manual and electromotive operation.The characteristics in accordance
with GB1984-2003 High voltage AC circuit breaker,JB3855-1998 3.6-4.5KV Indoor AC High voltage circuit breaker and
IEC standard 62271-100:2001 High voltage AC circuit breaker.
ΔApplying ambient conditions
1.Ambient temperature:-15ºC~+40ºC.
2.Relative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.
3.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa;the average pressure of a month should be no more than 1.8kPa.
4.The height above sea level:≤1000m.
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire,explosion,serious filth,chemical erosion and violent vibration.





Our Factory





Our Certificates


Welcome for enquiry and factory visit!
With Lateral Operating Mechanism
ΔGeneral Description
VS1/R-12 series of Indoor High Votage Vacuum Circuit Breaker With Lateral Operating Mechanism used spring to storage energy. The operating mechanism can be operated by two ways:by manual and electromotive operation.The characteristics in accordance
with GB1984-2003 High voltage AC circuit breaker,JB3855-1998 3.6-4.5KV Indoor AC High voltage circuit breaker and
IEC standard 62271-100:2001 High voltage AC circuit breaker.
ΔApplying ambient conditions
1.Ambient temperature:-15ºC~+40ºC.
2.Relative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.
3.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa;the average pressure of a month should be no more than 1.8kPa.
4.The height above sea level:≤1000m.
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire,explosion,serious filth,chemical erosion and violent vibration.





Our Factory





Our Certificates


Welcome for enquiry and factory visit!