Vacuum Switch Tube Indoor Load Breaking Switch White Ceramic Vacuum Interrupter

Price $78.00 Compare
Min Order 3 Pieces
Shipping From Hubei, China
Popularity 284 people viewed
Quantity
+-
 

Wuhan Feite Electric Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
VTF52401
DC/AC Vacuum Contactor
/
Indoor High-voltage
Electric
/
/
1/2/3
/
Three
Turn the Horizontal
Single Throw-in
/
Electric
ISO, IS9001, ISO9001, STL
Vacuum Interrupter
20years
Silver, Copper
Yes
Feite Brand
Pallet, Carton(Ploy Bags, Foam)
Circuit-Breaker Failure Protection
China
8535900090
Product Description
Product Description

Vacuum Switch Tube Indoor Load Breaking Switch White Ceramic Vacuum Interrupter

Vacuum arc extinguishing chamber, also known as vacuum switch tube, is the core component of the high voltage power switch, its main role is to cut off the arc and inhibit the electric current by its high inside insulation performance to avoid accidents.

Wuhan Feite Electric brand vacuum arc extinguishing chamber adopts a corrugated ceramic insulation shell, copper tungsten tungsten carbide alloy materials contact, using advanced one exhuast technology process makes the vacuum interrupter has the advantages of small volume, high insulating level, low closure value, long service lifetime, easy-maintenance, explosion-free, low noise, low maintenance costs, reliable operation and non-pollution etc.. The vacuum arc extinguishing chamber mainly been used in power transmission and distribution control system. It is also can be used in metallurgy, mine, petroleum, chemical industry, railway, broadcasting, communications, industrial high frequency heating power distribution system.




Main Technical Date

Parameter item UnitDate
Rated voltage                                            kv40.5
Rated current                                            A1250
Rated frequency                                         Hz50
Rated short-time power frequency withstand voltage(1min)     kv95
Rated lighting impulse withstand voltage                     kv185
Rated short-cricuit withstand currentkA20/25
Rated withstand current(peak)kA50/63
Rated short-cricuit making current              kA50/63
Rated cloaed-loop breaking currentA1250
Rated active load breaking current                    A1250
Rated cable charging breaking currentA21
Rated single capacitor bank breaking current                    A2000
Rated duration of short-circuit     S4
Mechanical life                                           times30000
Contact closing force due to bellows and atmosphere          N150±40
Counterforce at rated contact stroke                          N210±50
Circuit resistance at rated contact contact force                      μΩ≤ 30
Shelf life                                                  years20
Contact erosion limit                                       mm3
Weight of moving parts                                                                             kg≤ 1.3
Mechanical Data Required For Matched Vacuum Switchgear                                             
Rated contact strokemm20±1
2Average opening speed                                   m/s1.6±0.2
Average closing speed                                    m/s0.8±0.2
Added contact force                                       N1800/2200±200
Contact bouncing duration at closing operation                ms≤2
Contact bouncing bank amplitude of opening operation         mm≤1
Three-pole simultaneity                                     ms≤2

 

Company Profile

ABOUT OUR COMPANY

Wuhan Feite Electric Co.,Ltd is located at Wuhan city, Hubei Province which is the Eastcenter part of China. lt is specialized in producing vacuum interrupter and vacuumembedded poles.The company has developed 1.14KV-40.5KV vacuum switch tubes morethan 300 types,which can be widely used for various vacuum circuit breaker, vacuumcontactors, vacuum load breaker switches, auto re-closers,RMU etc.The company has full sets vacuum producing and testing equipment,with annualproduction of 600,000 vacuum tube production capacity, As an ISO09001:2008 certifiedcompany,our production process strictly conforms to quality management system.Wuhan Feite Electric Co.,Ltd is always supply you good quality products with reasonableand competitive prices.



vacuum interrupter for vacuum contactor voltage 1.14kv/3.6kv/7.2kv/12kv/24kv, rated current is 400A/630A/1250A, 10ka vacuum switchgear/vacuum circuit breaker


vacuum interrupter for vacuum contactor voltage 1.14kv/3.6kv/7.2kv/12kv/24kv, rated current is 400A/630A/1250A, 10ka vacuum switchgear/vacuum circuit breaker


3> Different Types Vacuum Interrupter and Embedded Poles
vacuum interrupter for vacuum contactor voltage 1.14kv/3.6kv/7.2kv/12kv/24kv, rated current is 400A/630A/1250A, 10ka vacuum switchgear/vacuum circuit breaker

 
Certifications

 


vacuum interrupter for vacuum contactor voltage 1.14kv/3.6kv/7.2kv/12kv/24kv, rated current is 400A/630A/1250A, 10ka vacuum switchgear/vacuum circuit breaker

Vacuum Interrupter and Embedded Poles Stock
vacuum interrupter for vacuum contactor voltage 1.14kv/3.6kv/7.2kv/12kv/24kv, rated current is 400A/630A/1250A, 10ka vacuum switchgear/vacuum circuit breaker


6> Company Introduction
vacuum interrupter for vacuum contactor voltage 1.14kv/3.6kv/7.2kv/12kv/24kv, rated current is 400A/630A/1250A, 10ka vacuum switchgear/vacuum circuit breaker
 
Packing

 

FAQ

1. Precheck before putting it into use.
Check id packing is in good condition. Check the appearance of vacuum interrupter and
Whether it corresponds to the test certificate after uppacking. When shaking the interrupter, the ceramic envelop should be integrated.Power frequency withstand voltage should be tested before operating vacuum interrupter. Clean the surface with a dry colth or alcohol damped cloth before testing. The normal way for testing is an follows: when in the clearance between open contacts applies with 70 percent of rated power frequency withstand voltage within 1 min. The vacuum interrupter will be qualified if there is no sudden change and trip phenomena in the pointer of the vacuum interrupter.

 
2. Mounting of vacuum interrupter
a.Clean the surface of vacuum interrupter with cotton or alcohol dipped silk cloth before mounting. Meanwhile clean the conducting pole and surface of electric connection in order that the vacuum interrupter can have good electric contact with the equipment.b.The interrupter should be adjusted in the line with the equipment after mounting. The mechanical date related to the interrupter must meet the given specification.

3.In mounting, attention should be paid to the following:
a.When operating, guide unite unit must be provided for the interrupter. The coaxality of moving conducting pole and axial line of interrupter must meet the requirement. There should not be torque force applied on the bellow.
b. When mounting, it is forbidden to beat or strike the interrupter envelop with hard things in case crack may occur to cause air leakage.
c.Take care to assure that the conducting pole must be coaxial with interrupter, and that the conducting pole must be vertical on the face of fixed end
d.Take care not to disassemble the interrupter repeatedly to prevent screw from slipping. There should not be twisting on the moving conducting pole and over press on bellow to avoid that any torque force and scratch may occur to bellow to reduce its service life.
e.During mounting, the force applied on the face of both ends should not go beyond the static relief pressure stipulated in the specification.

 

4. Application.
a. Check the vacuum interrupter periodically by the way power frequency withstand voltage. For this, please see subclause
b. Periodically check how burnout is going on for contacts. When it comes to the burnout mark of moving conducting pole, it shows that the vacuum interrupter has finished its electrical endurance, and it should be replaced.

Message Type