CL-CW
One
8~60 Deg C
Common Heat Pump
Ground-source
Circulating Heat
Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
CE, ISO9001, CCC, RoHS, SASO
8 Deg C
60 Deg C
R410A
11~160kw
KONNEN
Plywood Case with Pallet
CE
China
8418612090
Product Description
WATER SOURCE HEAT PUMP FOR COOLING AND HEATING, WATER TO WATER HEAT PUMP FOR COOLING AND HEATING, BRINE TO WATER HEAT PUMP FOR COOLING AND HEATING, WITH PANASONIC OR COPELAND COMPRESSOR AND R410A REFRIGERANT:
WE SUPPLY OEM SERVICE!
KONNEN NEW FACTORY 2017(HEAT PUMP + WATER TANK + CONTROLLER):

WHY US:

KONNEN NEW PROJECTS:
KONNEN HEAT PUMPS FOR EXPORTING:

WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:

PRODUCT FEATURES:

PARAMETERS TABLE:
HEAT PUMP, WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, GROUND SOURCE HEAT PUMP, GEOTHERMAL HEAT PUMP.
* Panasonic compressor & R410a refrigerant or Copeland compressor & R410a refrigerant; | |||||||
* Preservative oil for copper tubes and all important part of cabinet; | |||||||
* Chinese No.1 brand "ND" shell & tube heat exchanger; | |||||||
* Schneider AC contactor and relay | |||||||
* Japan "Saginomiya" or "Sanhua" electronic expansion valve; | |||||||
* KONNEN LCD controller; | |||||||
* Delivery time: 20~25 days; | |||||||
* Payment term: T/T 30% in advance and T/T 70% before delivery; | |||||||
* Warranty time: 24 months after delivery. |
WE SUPPLY OEM SERVICE!
KONNEN NEW FACTORY 2017(HEAT PUMP + WATER TANK + CONTROLLER):

WHY US:

KONNEN NEW PROJECTS:


WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:

PRODUCT FEATURES:

PARAMETERS TABLE:
CL11s-CW5 | CL17s-CW5 | CL11-CW5 | CL17-CW5 | CL24-CW5 | CL34-CW10 | CL48-CW10 | CL68-CW20 | CL80-CW20 | CL120-CW20 | CL160-CW20 | |||
Underground water open loop | Rated cooling capacity | KW | 11 | 17 | 11 | 17 | 24 | 34 | 48 | 68 | 80 | 120 | 160 |
Rated input power for cooling | KW | 2.15 | 3.34 | 2.11 | 3.20 | 4.72 | 6.53 | 9.18 | 13.18 | 15.72 | 23.35 | 31.56 | |
Rated input current for cooling | A | 9.55 | 14.84 | 3.98 | 6.04 | 8.91 | 12.33 | 17.35 | 24.91 | 29.71 | 44.12 | 59.64 | |
Cooling performance coefficient (EER) | / | 5.12 | 5.09 | 5.22 | 5.32 | 5.09 | 5.21 | 5.23 | 5.16 | 5.09 | 5.14 | 5.07 | |
Rated heating capacity | KW | 9.5 | 16 | 9.5 | 16 | 22 | 32 | 45 | 65 | 75 | 115 | 150 | |
Rated input power for heating | KW | 2.59 | 4.38 | 2.59 | 4.31 | 6.09 | 8.86 | 12.33 | 18.01 | 21.01 | 32.39 | 41.78 | |
Rated input current for heating | A | 12.33 | 20.87 | 4.89 | 8.15 | 11.52 | 16.75 | 23.30 | 34.03 | 39.71 | 61.23 | 78.97 | |
Heating performance coefficient (COP) | / | 3.67 | 3.65 | 3.67 | 3.71 | 3.61 | 3.61 | 3.65 | 3.61 | 3.57 | 3.55 | 3.59 | |
Application side heat exchanger water flow | M3/h | 1.89 | 2.92 | 1.89 | 2.92 | 4.13 | 5.85 | 8.26 | 11.70 | 13.76 | 20.64 | 27.52 | |
Heat source side heat exchanger water flow | M3/h | 1.03 | 1.59 | 1.03 | 1.59 | 2.25 | 3.19 | 4.50 | 6.38 | 7.51 | 11.26 | 15.01 | |
Ground source closed loop | Rated cooling capacity | KW | 10 | 16 | 10 | 16 | 22 | 32 | 46 | 64 | 76 | 114 | 150 |
Rated input power for cooling | KW | 1.96 | 3.17 | 1.95 | 3.13 | 4.38 | 6.17 | 8.83 | 12.48 | 14.90 | 22.27 | 29.64 | |
Rated input current for cooling | A | 8.70 | 14.11 | 3.68 | 5.91 | 8.28 | 11.65 | 16.69 | 23.58 | 28.16 | 42.08 | 56.03 | |
Cooling performance coefficient (EER) | / | 5.11 | 5.04 | 5.13 | 5.12 | 5.02 | 5.19 | 5.21 | 5.13 | 5.10 | 5.12 | 5.06 | |
Rated heating capacity | KW | 8 | 12 | 8 | 12 | 16 | 24 | 33 | 48 | 57 | 86 | 115 | |
Rated input power for heating | KW | 3.07 | 4.43 | 3.04 | 4.58 | 5.99 | 9.20 | 12.60 | 18.39 | 22.01 | 32.95 | 43.73 | |
Rated input current for heating | A | 13.27 | 19.17 | 5.66 | 8.52 | 11.15 | 17.10 | 23.43 | 34.21 | 40.93 | 61.29 | 81.33 | |
Heating performance coefficient (COP) | / | 2.61 | 2.71 | 2.63 | 2.62 | 2.67 | 2.61 | 2.62 | 2.61 | 2.59 | 2.61 | 2.63 | |
Application side heat exchanger water flow | M3/h | 1.38 | 2.06 | 1.38 | 2.06 | 2.75 | 4.13 | 5.68 | 8.26 | 9.80 | 14.79 | 19.78 | |
Heat source side heat exchanger water flow | M3/h | 1.72 | 2.58 | 1.72 | 2.58 | 3.44 | 5.16 | 7.10 | 10.32 | 12.26 | 18.49 | 24.73 | |
Power supply | 1N 220V/50Hz (Special power supply for option) | 3N 380V/50Hz(Special power supply for option) | |||||||||||
Compressor | Type | Hermetic scroll type | |||||||||||
Quantity | PCS | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 3 | 4 | |
Heat source side heat exchanger | Type | Shell & coil(tube) heat exchanger | |||||||||||
Connection size | DN | DN20 | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN65 | DN65 | DN80 | |
Application side heat exchanger | Type | Shell & coil(tube) heat exchanger | |||||||||||
Connection size | DN | DN20 | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN65 | DN65 | DN80 | |
Protections | 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc. | ||||||||||||
Refrigerant | Type | R410A | |||||||||||
Quantity | KG | 2.6 | 3.3 | 2.6 | 3.3 | 4.2 | 3.3x2 | 4.2x2 | 6.6x2 | 7.6x2 | 7.6x3 | 7.6x4 | |
Dimension | mm | 790x415x590 | 790x710x950 | 2000x1000x1600 | |||||||||
Wooden case package dimensions(L*W*H) | mm | 836x461x752 | 836x756x1112 | 2056x1056x1768 | |||||||||
Net weight | KG | 68 | 95 | 65 | 95 | 135 | 195 | 320 | 795 | 885 | 1180 | 1210 | |
Gross weight | KG | 78 | 105 | 75 | 105 | 145 | 215 | 340 | 830 | 920 | 1215 | 1245 | |
Noise | DB(A) | ≤53 | ≤55 | ≤55 | ≤55 | ≤58 | ≤58 | ≤62 | ≤65 | ≤70 | ≤75 | ≤75 | |
Note: | |||||||||||||
1. Underground water open loop type cooling standard condition: application side water input/output temperature 12ºC/7ºC; source side water input/output temperature 18ºC/29ºC. Underground water open loop type heating standard condition: application side water input/output temperature 40ºC/45ºC; source side water input/output temperature 15ºC/-a. | |||||||||||||
2. Ground source closed loop type cooling standard condition: application side water input/output temperature 12ºC/7ºC; source side water input/output temperature 25ºC/30ºC Ground source closed loop type heating standard condition: application side water input/output temperature 40ºC/45ºC ; source side water input/output temperature 5ºC/-a. | |||||||||||||
3. "-a " means the water flow under cooling standard condition. | |||||||||||||
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable, or refer to us for any information. Our company keeps the right to interpret. |
HEAT PUMP, WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, GROUND SOURCE HEAT PUMP, GEOTHERMAL HEAT PUMP.