Wilo Cronoline Il E Single Stage Series Structure CNC Circulating Pump for Heating and Irrigation

Price $10000.00 Compare
Min Order 1 Piece
Shipping From Tianjin, China
Popularity 419 people viewed
Quantity
+-
 

Tianjin Shiny-Metals Technology Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
Wilo-CronoLine-IL-E
80m
550m³/H
CNC
Single-Stage Pump
13bar/16bar
Single Suction Pump
Vertical Pump
Verticaljoint Surface Pump
Since Irrigation Centrifugal Pumps
Closed
Pump, Hot Water Heating System, Cooling Water and Cold W
-20 °c to +60 °c
0 °c to +40 °c
-20 °c to +140 °c
F
IP55
Wilo
Wooden Chest
Series structure
Germany
Product Description
Wilo-CronoLine-IL-E is a series structure CNC dry rotor single head pump with flange connection and automatic power regulation.
Product Description                                                              

 
Wilo-CronoLine-IL-E adopts an integrated electronic power regulation device, which can save energy and is a professional device that complies with the EN 61000-3-2 standard.
Flow range  : <550m³/h
Lift range : ≤80m
Max.operating pressure at different fluid temperature : 13bar/16bar
Temperature range : -20ºC~+140ºC
Nominal diameter :DN 40 to DN 200

Aplication field :The CronoLine-IL-E series is mainly suitable for hot water heating systems, cooling water and cold water circulation circuits, industrial circulation systems, heat transfer circulation circuits, and irrigation systems
 Your advantages                                                             
  • Energy savings due to integrated electronic power adjustment
  • Optional interfaces for bus communication using plug-in IF-Modules
  • Simple operation with Green Button Technology and display
  • Integrated dual pump management
  • Integrated full motor protection (PTC thermistor sensor) with trip electronics

Equipment/function

Operating modes                                                                   
  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • PID-Control
  • Constant speed (n=constant)
Manual operation level                                                         
  • Green button and display
  • Differential pressure setpoint setting
  • Setting the speed (manual control mode)
  • Setting the operating mode
  • Setting the pump ON/OFF
  • Configuration of all operating parameters
  • Fault acknowledgement
External control functions                                                   
  • "Overriding Off" control input
  • "External pump cycling" control input (only effective in twin-head pump operation)
  • Analogue input 0 - 10 V, 0 - 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 2 - 10 V, 4 - 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 0 - 10 V for actual value signal from pressure sensor
  • Analogue input 2 - 10 V, 0 - 20 mA, 4 - 20 mA for actual value signal from pressure sensor
Signal and display functions                                                 
  • Collective fault signal SSM
  • Collective run signal SBM
Data exchange                                                                       
  • Infrared interface for wireless data exchange with IR-Stick
  • Plug-in position for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions                                                                     
  • Full motor protection with integrated trip electronics
  • Access disable
Dual pump management (twin-head pump or 2 x single pumps) 
  • Main/standby operation (automatic fault-actuated switchover)
  • Pump cycling main/standby operation after 24 hours
  • Parallel operation
  • Parallel operation (efficiency-optimised peak-load activation and deactivation)
Typekey                                                                       
 

Example

IL-E 50/190-11/2-R1

IL-E

In-line pump with electronic control

50

Nominal diameter DN of the pipe connection

190

Nominal impeller diameter

11

Rated power P2 in kW

2

Number of poles

R1

Version without pressure sensor

  

 Technical data                                                                                 
  • Permissible temperature range of -20 °C to +140 °C
  • Mechanical seal for pumping water up to Tmax = +140 °C. Up to T ≤ +40 °C, a glycol admixture of 20 % to 40 % by volume is permissible. An alternative mechanical seal must be provided for water-glycol mixtures with a glycol content of > 40% to max. 50% by volume and a fluid temperature of > +40 °C to max. +120 °C or other fluids that differ from water. When using water-glycol mixtures, the use of an S1 variant with a corresponding mechanical seal is generally recommended.
  • Mains connection
    • 3~440 V ±10 %, 50/60 Hz
    • 3~400 V ±10%, 50/60 Hz
    • 3~380 V -5% +10%, 50/60 Hz
  • Compliance with electromagnetic compatibility without additional measures:
    • Interference emission for residential environment according to EN 61800-3:2018
    • Interference immunity for industrial environments according to EN 61800-3:2018
  • Protection class IP55
  • Nominal diameter DN 40 to DN 200
  • Max. operating pressure 16 bar up to +120 °C, 13 bar up to +140 °C
Materials                                                                     
  • Pump housing and lantern: EN-GJL-250
  • Impeller
    • Standard version: EN-GJL-200
    • Special version: Bronze CuSn 10
    • Special version: Stainless steel 1.4408
  • Shaft: 1.4122
  • Mechanical seal: AQEGG; other mechanical seals on request

Construction                                                                     

Single-stage, low-pressure centrifugal pump in in-line design with

  • Mechanical seal
  • Flange connection
  • Lantern
  • Coupling
  • Drive with integrated electronic speed control
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA