Wilson 16.5kVA/13.2kw Diesel Generator Set

Price $10000.00 Compare
Min Order 1 Piece
Shipping From Beijing, China
Popularity 233 people viewed
Quantity
+-
 

Beijing Xinda Creation Machinery Equipment Co., Ltd.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
P18-6(Skid)
Lifetime
12 Months From Date of Start-up
Micro-Computer Control Automatic Diesel Generator
Portable
Four Stroke
Water Cooling
AC Three Phase
Speed
Land Use
Common Units
Automation Type
AC Rotating Exciter
400/230 V, 50 Hz; 220/127 V, 60 Hz
365 (805) Kg
372 (820) Kg
Heavy Duty Fabricated Steel
FG Wilson
Moisture-Proof Film
China
Product Description
Product Description

Wilson Advantage

1.Product advantages
*Start-up performance: It takes 5 seconds to reach a stable state after starting the cranking, and it takes about 15 seconds to reach full load.
*Loading capacity:
One-step loading capacity exceeds 50%

*Power density:High power density, small unit size
*Maintenance of the economy:Some parts of the 720-2000kw unit are interchangeable to reduce costs - the advantage of the high power section
*Extended warranty service:60-month extended warranty service


2.service advantage
*Customized services Wilson has a solution team of more than 200 people to design and produce customized products according to customers' special needs.
*Advanced control and parallel system

*Remote cooling device
*Emission silencer system
*Rainproof and anti-speaker box
*High insulation level
*Customized testing
 

3. Complete solution-pre-sales support:
*Equipment load calculation and generator set selection: According to the project equipment load requirements, calculate the actual power supply demand, taking into account reliability and economy;


*Deepening of the engine room design: Based on project requirements and actual site conditions, deepen the diesel engine room design plan and provide professional suggestions; including diesel engine load-bearing foundation, engine room ventilation system, oil system, cable bridge, distribution cabinet layout, diesel engine room Hoisting etc.

4. Complete solution-after-sales support
*Provide professional product training
*FG Wilson Original Parts Consulting Help
*Ensure timely supply and delivery of parts
*Complete warranty, extended warranty and customer service agreements


Product certification and qualifications

P18-6 model product details



Ratings and Performance Data
Engine Make Perkins
Engine Model: 404D-22G1
Alternator Make FG Wilson
Alternator Model: FGL10040
Control Panel: FG100
Base Frame: Heavy Duty Fabricated Steel
Circuit Breaker Type: 3 Pole MCB
Frequency: 50 HZ60 HZ
Engine Speed: RPMrpm15001800
Fuel Tank Capacity:litres (USgal) 
Fuel Consumption Primelitres (USgal)/hr4.4 (1.2)5.3 (1.4)
Fuel Consumption Standbylitres (USgal)/hr4.8 (1.3)5.8 (1.5)
 
Engine Technical Data
No. of Cylinders
Alignment
Cycle
Bore
Stroke
Induction
Cooling Method
Governing Type
Governing Class
Compression Ratio
Displacement
Moment of Inertia:
Voltage
Ground
Battery Charger Amps
Engine Weight Dry
Engine Weight Wet



mm (in)
mm (in)






L (cu. in)
kg  (lb/in²)



kg (lb)
kg (lb)
4
IN LINE
4 STROKE
84 (3.3)
100 (3.9)
NATURALLY ASPIRATED
WATER
MECHANICAL
ISO 8528
23.3:1
2.2 (135.2)
2.724 (9308)
12
Negative
65
242 (534)
251 (554)
Engine Performance Data50 Hz60 Hz
Engine Speedrpm15001800
Gross Engine Power PrimekW (hp)16.2 (22)19.4 (26)
Gross Engine Power StandbykW (hp)18 (24)21.5 (29)
BMEP PrimekPa (psi)585 (84.8)583 (84.6)
BMEP StandbykPa (psi)649 (94.2)647 (93.8)

Fuel System
Fuel Filter Type:  Replaceable Element
Recommended Fuel: Class A2 Diesel
Fuel Consumption at 110 % Load100 % Load75 % Load50 % Load
50 Hz Prime:l/hr (USgal/hr)4.8 (1.3)4.4 (1.2)3.4 (0.9)2.6 (0.7)
50 Hz Standbyl/hr (USgal/hr)-4.8 (1.3)3.7 (1)2.7 (0.7)
60 Hz Primel/hr (USgal/hr)5.8 (1.5)5.3 (1.4)4.1 (1.1)3.2 (0.8)
60 Hz Standbyl/hr (USgal/hr)-5.8 (1.5)4.5 (1.2)3.3 (0.9)
 
Air System50 Hz60 Hz
Air Filter Type: Replaceable Element
Combustion Air Flow Prime
Combustion Air Flow Standby
Max. Combustion Air Intake Restriction
m³/min (cfm)
m³/min (cfm)
kPa
1.5 (51)
1.5 (51) 3 (12)
1.7 (61)
1.7 (61) 3 (12)
 
Cooling System50 Hz60 Hz
Cooling System Capacityl (USgal)6.5 (1.7)6.5 (1.7)
Water Pump Type: Centrifugal
Heat Rejected to Water & Lube Oil: PrimekW (Btu/min)13.7 (779)                                               15.5 (881)
Heat Rejected to Water & Lube Oil: StandbykW (Btu/min)15.2 (864)                                               17.2 (978)
Heat Radiation to Room*: PrimekW (Btu/min)5 (284)5.7 (324)
Heat Radiation to Room*: StandbykW (Btu/min)5.8 (330)6.3 (185)
Radiator Fan Load:kW (hp)0.2 (0.3)0.4 (0.5)
Radiator Cooling Airflow:m³/min (cfm)33 (1165)41.4 (1462)
External Restriction to Cooling Airflow:Pa (in H2O)125 (0.5)125 (0.5)
*: Heat radiated from engine and alternator
Designed to operate in ambient conditions up to 50°C (122°F).
Contact your local FG Wilson Dealer for power ratings at specific site conditions.
 
Lubrication System
Oil Filter Type: Spin-on, Full flow
Total Oil Capacity:
Oil Pan Capacity:
Oil Type:
l (USgal)
l (USgal)
10.6 (2.8)
8.9 (2.4)
API CH4 15W-40
Oil Cooling Method: N/A
 
Exhaust System 50 Hz60 Hz
Maximum Allowable Back Pressure:kPa (inHg)10.2 (3)10.2 (3)
Exhaust Gas Flow: Primem³/min (cfm)3 (105)3.9 (138)
Exhaust Gas Flow: Standbym³/min (cfm)3.2 (114)4.3 (151)
Exhaust Gas Temperature: Prime°C (°F)364 (687)396 (745)
Exhaust Gas Temperature: Standby°C (°F)413 (776)459 (858)
 
Alternator Physical Data
No. of Bearings:1
Insulation Class:
Winding Pitch:
Winding Code
Wires:
Ingress Protection Rating:
Excitation System:
AVR Model:
H
2/3
6S/6P
4
IP23
SHUNT
R120
* dependant on voltage code selected
Alternator Operating Data
Overspeed: rpm2250
Voltage Regulation: (Steady state) Wave Form NEMA = TIF:
Wave Form IEC = THF:
Total Harmonic content LL/LN:
Radio Interference:
Radiant Heat: 50 Hz
Radiant Heat: 60 Hz
%

%
%

kW (Btu/min)
kW (Btu/min)
+/- 0.5
50
2
3.5
EN61000-6
2.7 (154)
3.1 (176)
 
Alternator Performance Data 50 Hz:

Voltage Code
415/240 V400/230 V380/220 V 
Motor Starting Capability* Short Circuit Capacity**
Reactances
kVA
%
Xd
X'd
X"d
28
0
1.954
0.172
0.093
26
0
2.104
0.186
0.093
24
0
2.331
0.206
0.103

0

Alternator Performance Data 60 Hz

Voltage Code
    
220/127 V
Motor Starting Capability* Short Circuit Capacity**
Reactances
kVA
%
Xd
X'd
X"d

0

0

0

0
26
0
2.529
0.223
0.112
Reactances shown are applicable to prime ratings.
*Based on 30% voltage dip at 0.6 power factor.
** With optional independant excitation system (PMG / AUX winding)

Introduction to other series of Wilson products
Body details
Open unit series:

Closed unit series:
Support customization according to needs

Putting You in Control
Whatever your power requirements, FG Wilson can provide a control system to suit your needs.   Our generator set experts design and validate FG Wilson control systems to optimise your generator set performance and put you in control.
All FG Wilson control panels are compact, versatile and easy to use. Our comprehensive range includes key-start analogue control panels for straightforward functionality and reliability; digital control panels suitable for use in mains failure applications, providing advanced metering, protection and diagnostics; and the next generation of advanced synchronising panels with integrated load management capability, suitable for synchronising up to 32 generator sets.
Our range of load transfer panels are designed to enhance the operation of your standby generator set in conjunction with our electronic control panels, to provide automatic control of your standby generator set in the event of a power outage, 24 hours a day, 365 days a year.
For more challenging power requirements, our Power Solutions Team is dedicated to the design and production of bespoke control systems to meet your individual needs, regardless of complexity.

Factory photos

Applications

List of price models
model numberVoltage, FrequencyPrime PowerStandby PowerEngine MakeEngine modelAlternator MakeAlternator modelFuel consumption
(L/h)
Dimensions
(mm)
Weight
KVAKWKVAKW Prime StandbyDry(kg) Wet(kg)
P7.5-1S230 V, 50 Hz6.86.87.57.5Perkins403A-11G1FG WilsonFGL100302.5 (0.7)2.8 (0.7)1550×620×1020233238
P7.5-4S230 V, 50 Hz6.86.87.57.5Perkins403D-11GFG WilsonFGL100302.5 (0.7)2.8 (0.7)1550×620×1020233238
240/120 V, 60 Hz888.88.8Perkins403D-11GFG WilsonFGL100302.9 (0.8)3.3 (0.9)1550×620×1020233238
P9.5-1400/230 V, 50 Hz8.56.89.57.6Perkins403A-11G1FG WilsonFGL100202.5 (0.7)2.8 (0.7)1550×620×1020226231
P9.5-4400/230 V, 50 Hz8.56.89.57.6Perkins403D-11GFG WilsonFGL100202.7 (0.7)3 (0.8)1550×620×1020226231
220/127 V, 60 Hz108118.8Perkins403D-11GFG WilsonFGL100202.9 (0.8)2.9 (0.8)1550×620×1020226231
P11-6S230 V, 50 Hz9.99.910.910.9Perkins403D-15GFG WilsonFGL100303.6 (1)4 (1.1)1550×620×1020309315
240/120 V, 60 Hz11.811.812.912.9Perkins403D-15GFG WilsonFGL100304.3 (1.1)4.8 (1.3)1550×620×1020309315
P13.5-6400/230 V, 50 Hz12.49.9213.510.8Perkins403D-15GFG WilsonFGL100203.6 (1)4 (1.1)1550×620×1020302308
220/127 V, 60 Hz151216.413.12Perkins403D-15GFG WilsonFGL100204.3 (1.1)4.8 (1.3)1550×620×1020302308
P14-6S230 V, 50 Hz13131414Perkins404D-22G1FG WilsonFGL100404.3 (1.1)4.6 (1.2)1550×620×1020370377
240/120 V, 60 Hz14.514.51616Perkins404D-22G1FG WilsonFGL100404.8 (1.3)5.3 (1.4)1550×620×1020370377
P16.5-1S230 V, 50 Hz151516.516.5Perkins404A-22G1FG WilsonFGL100605 (1.3)5.6 (1.5)1550×620×1020378385
P16.5-6S230 V, 50 Hz151516.516.5Perkins404D-22GLeroy SomerLLB1114M4.9 (1.3)5.5 (1.5)1500×620×1115447454
240/120 V, 60 Hz17.617.619.419.4Perkins404D-22GLeroy SomerLLB1114M5.7 (1.5)6.3 (1.7)1500×620×1115447454
P16-1 (skid)400/230V, 50 Hz14.511.61612.8Perkins 403A-15G2Leroy SomerLL1114M4.1 (1.1)4.7 (1.2)1500×860×895333339
P18-6400/230 V, 50 Hz16.513.21814.4Perkins404D-22G1FG WilsonFGL100404.4 (1.2)4.8 (1.3)1550×620×1020365372
220/127 V, 60 Hz20162217.6Perkins404D-22G1FG WilsonFGL100405.3 (1.4)5.8 (1.5)1550×620×1020365372
P22-1400/230 V, 50 Hz20162217.6Perkins404A-22G1FG WilsonFGL100605.4 (1.4)6.1 (1.6)1550×620×1020378385
P22-6 (skid)400/230V, 50 Hz20162217.6Perkins404D-22GLeroy SomerLL1114M5.3 (1.4)5.9 (1.6)1500×860×895383389
220/127V, 60 Hz22.5182520Perkins404D-22GLeroy SomerLL1114M5.8 (1.5)6.5 (1.7)1500×860×895383389
P26-3S230 V, 50 Hz24242626Perkins1103A-33G1FG WilsonFGL20050-M6.8 (1.8)7.4 (2)1570×760×1231695708
P26-6S230 V, 50 Hz24242626Perkins1103D-33G3FG WilsonFGL20050-M7.3 (1.9)7.8 (2.1)1570×760×1231695708
P33-3400/230 V, 50 Hz30243326.4Perkins1103A-33G1FG WilsonFGL200306.9 (1.8)7.7 (2)1570×760×1231660673
P33-6400/230 V, 50 Hz30243326.4Perkins1103D-33G3FG WilsonFGL200307.4 (2)8.2 (2.2)1570×760×1231660673
P50-3400/230 V, 50 Hz45365040Perkins1103A-33TG1FG WilsonFGL2006010.5 (2.8)11.7 (3.1)1680×760×1330751764
P50-5S230 V, 50 Hz45455050Perkins1103A-33TG2FG WilsonFGL30030-M12.6 (3.3)14.1 (3.7)1680×760×1330864887
P55-3400/230 V, 50 Hz50405544Perkins1103A-33TG2FG WilsonFGL2007011.6 (3.1)12.8 (3.4)1680×760×1330756769
P55-4400/230 V, 50 Hz50405544Perkins1104C-44TG2/3FG WilsonFGL2007015.9 (4.2)17.4 (4.6)1870×840×1333818831
P55-6S230 V, 50 Hz50505555Perkins1104D-44TG2/3FG WilsonFGL30030-M17.1 (4.5)19.1 (5)1870×840×1333936949
P65-5400/230 V, 50 Hz60486552Perkins1103A-33TG2FG WilsonFGL2008013.7 (3.6)15 (4)1680×760×1330765778
P65-6400/230 V, 50 Hz60486552Perkins1104D-44TG2/3FG WilsonFGL2008016.6 (4.4)18.3 (4.8)1870×840×1333827840
P88-3400/230 V, 50 Hz80648870.4Perkins1104A-44TG2FG WilsonFGL3002018.2 (4.8)20.1 (5.3)1870×840×1333939952
P88-6400/230 V, 50 Hz80648870.4Perkins1104D-E44TAG1FG WilsonFGL3002019.4 (5.1)21 (5.5)1980×890×139810681085
P90-3S230 V, 50 Hz82829090Perkins1104C-44TAG2FG WilsonFGL30100-M22.1 (5.8)24.3 (6.4)1980×890×137411511169
P90-6S230 V, 50 Hz81.781.789.889.8Perkins1104D-E44TAG2FG WilsonFGL30100-M23.6 (6.2)24.9 (6.6)1980×890×137412291246
P110-3400/230 V, 50 Hz1008011088Perkins1104C-44TAG2FG WilsonFGL3004021.7 (5.7)23.9 (6.3)1980×890×137410191036
P110-6400/230 V, 50 Hz1008011088Perkins1104D-E44TAG2FG WilsonFGL3004023.8 (6.3)25.5 (6.7)1980×890×137411361156
P150-5400V, 50 Hz135108150120Perkins1106A-70TG1MarelliMJB225LA429.9 (7.9)33.4 (8.8)2450×1010×154414071428
480V, 60 Hz150120165132Perkins1106A-70TG1MarelliMJB225LA433.1 (8.7)36.7 (9.7)2450×1010×154414071428
P165-5400V, 50 Hz150120165132Perkins1106A-70TAG2MarelliMJB 250 MA432.4 (8.6)35.1 (9.3)2450×1010×154415451566
480V, 60 Hz168.8132187.5150Perkins1106A-70TAG2MarelliMJB 250 MA437.9 (10.0)41.6 (11.0)2450×1010×154415451566
P200-3400V, 50 Hz180144200160Perkins1106A-70TAG3MarelliMJB 250 MB439.8 (10.5)43.2 (11.4)2510×1010×164015521579
480V, 60 Hz200160218.8175Perkins1106A-70TAG3MarelliMJB 250 MB446.5 (12.3)50.6 (13.4)2510×1010×164015521579
P220-3400/230 V, 50 Hz200160220176Perkins1106A-70TAG4FG WilsonFGL3012045.1 (11.9)49 (12.9)2510×1010×164015061522
P249-5-60Hz480/277V, 60 Hz225180250200Perkins1506A-E88TAG2Leroy SomerLL5114F49.7 (13.1)54.6 (14.4)2662×1071×181819521985
P250-5400/230 V, 50 Hz230184250200Perkins1506A-E88TAG2Leroy SomerLL5114H47.2 (12.5)50.7 (13.4)2662×1071×181820352068
P275-2400/230 V, 50 Hz250200275220Perkins1506D-E88TAG4Leroy SomerLL5114H56.6 (15)60.6 (16)2662×1071×181820352068
P275-5400/230 V, 50 Hz250200275220Perkins1506A-E88TAG3Leroy SomerLL5114H53.8 (14.2)59.2 (15.6)2662×1071×181820352068
P300-4400/230 V, 50 Hz275220300240Perkins1506D-E88TAG4FG WilsonFG26A23060.2 (15.9)64.3 (17)2675×1071×181820772100
P300-5400/230 V, 50 Hz275220300240Perkins1506A-E88TAG4FG WilsonFG26A23059 (15.6)64.5 (17)2675×1071×181820772100
P313-5-60Hz480/277V, 60 Hz281.3225.04312.5250Perkins1506A-E88TAG3Leroy SomerLL5114H60.8 (16.1)67.6 (17.9)2662×1071×181820352068
P330-5400/230 V, 50 Hz300240330264Perkins1506A-E88TAG5FG WilsonFG26A25062.8 (16.6)70.1 (18.5)2785×1071×181822282261
P344-5-60Hz480/277V, 60 Hz312.5250343.8275.04Perkins1506A-E88TAG4FG WilsonFG26A25066.7 (17.6)73.7 (19.5)2785×1071×181822282261
P375-4-60Hz480/277V, 60 Hz343.8275.04375300Perkins1506D-E88TAG4FG WilsonFG26A25073.3 (19.4)80.5 (21.3)2785×1071×181822282261
P375-5-60Hz480/277V, 60 Hz337.5270375300Perkins1506A-E88TAG5FG WilsonFG26A25071.9 (19)80.5 (21.3)2785×1071×181822282261
P400-3-SA400/230 V, 50 Hz350280400320Perkins2206A-E13TAG2FG WilsonFG29A28068.6 (18.1)77.8 (20.6)3800×1131×215631033161
P438-3-SA-60Hz480/277V, 60 Hz400320437.5350Perkins2206A-E13TAG5FG WilsonFG29A28080.4 (21.2)88.1 (23.3)3800×1131×215631033161
P450-2-SA400/230 V, 50 Hz400320450360Perkins2206D-E13TAG3AFG WilsonFG29A32088.5 (23.4)97.8 (25.8)3800×1131×215631753233
P450-3-SA400/230 V, 50 Hz400320450360Perkins2206A-E13TAG3FG WilsonFG29A32078.2 (20.7)87.2 (23)3800×1131×215631953253
P500-3-SA400/230 V, 50 Hz450360500400Perkins2506A-E15TAG1FG WilsonFG29A36091.3 (24.1)101.5 (26.8)3800×1131×221536033661
P501-3-SA-60Hz480/277V, 60 Hz437.5350500400Perkins2206A-E13TAG6FG WilsonFG29A32087.8 (23.2)99.4 (26.3)3800×1131×215631953253
P550-2-SA400/230 V, 50 Hz500400550540Perkins2506D-E15TAG2FG WilsonFG29A400104 (27.5)113.9 (30.1)3787×1481×2193.437843832
P550-3-SA400/230 V, 50 Hz500400550540Perkins2506A-E15TAG2FG WilsonFG29A40097.2 (25.7)107.4 (28.4)3800×1131×221536413699
P563-3-SA-60Hz480/277V, 60 Hz512.5410562.5450Perkins2506A-E15TAG3FG WilsonFG29A360101.6 (26.8)111.3 (29.4)3800×1131×221536033661
P605-3400/230 V, 50 Hz550440605484Perkins2806A-E18TAG1FG WilsonFG33A450107.4 (28.4)119 (31.4)3900×1461×215641344202
P625-3-SA-60Hz480/277V, 60 Hz568.8455.04625500Perkins2506A-E15TAG4FG WilsonFG29A400112.8 (29.8)123.2 (32.5)3800×1131×221536413699
P660-3400/230 V, 50 Hz600480660528Perkins2806A-E18TAG1AFG WilsonFG33A500118.5 (31.3)131.1 (34.6)3900×1461×215642744342
P688-3-60Hz480/277V, 60 Hz625500687.5550Perkins2806A-E18TAG1AFG WilsonFG33A500124.6 (32.9)138.2 (36.5)3900×1461×215642744342
P715-3400/230 V, 50 Hz650520715572Perkins2806A-E18TAG2FG WilsonFG33A560127.6 (33.7)142 (37.5)3900×1461×215644544522
P750-3-60Hz480/277V, 60 Hz681.3545.04750600Perkins2806A-E18TAG3FG WilsonFG33A500138.9 (36.7)155 (40.9)3900×1461×215642744342
P780-1-SA400/230 V, 50 Hz706564.8780624Perkins2806A-E18TTAG4Leroy SomerLL7224J144.2 (38.1)160.6 (42.4)4130×1690×257048694979
P813-1-SA-60Hz480/277V, 60 Hz750600812.5650Perkins2806A-E18TTAG6ALeroy SomerLL7224H160.7 (42.5)176 (46.5)4130×1690×257047244834
P850-1-SA400/230 V, 50 Hz770616850680Perkins2806A-E18TTAG5Leroy SomerLL7224L160.3 (42.3)179.9 (47.5)4130×1690×257049305040
P895-1-SA-60Hz480/277V, 60 Hz812.5650895710Perkins2806A-E18TTAG6ALeroy SomerLL7224J172.8 (45.6)192 (50.7)4130×1690×257048694979
P938-1-60Hz480/277V, 60 Hz850680937.5750Perkins2806A-E18TTAG7Leroy SomerLL7224L183.3 (48.4)204.7 (54.1)4130×1690×257049305040
P900-1400/230 V, 50 Hz800640892713.6Perkins4006-23TAG3AFG WilsonFGL70030172.9 (45.7)195.5 (51.6)4280×1731×237958185938
P1000-1400/230 V, 50 Hz9107281000800Perkins4008TAG1AFG WilsonFGL70040191.8 (50.7)213.9 (56.5)4788×2046×241970327145
P1001-1-60Hz480/277V, 60 Hz9007201000800Perkins4008TAG1ALeroy SomerLL7224N198.3 (52.4)223.2 (59)4788×2046×241970887201
P1100-1400/230 V, 50 Hz10008001100880Perkins4008TAG2AFG WilsonFGL70050214 (56.5)240 (63.4)4788×2046×241971117224
P1101-1-60Hz480/277V, 60 Hz10008001100880Perkins4008TAG2ALeroy SomerLL7224P221.2 (58.4)244.4 (64.6)4788×2046×241971377250
P1250-1400/230 V, 50 Hz112590012501000Perkins4008-30TAG3Leroy SomerLL8224H240.1 (63.4)266.3 (70.3)4789×2197×206976137753
P1375-1400/230 V, 50 Hz1250100013751100Perkins4012-46TWG2ALeroy SomerLL8224H258 (68.2)284.9 (75.3)4788×1895×244088849080
480/277V, 60 Hz1250100013751100Perkins4012-46TWG2ALeroy SomerLL8224H266 (70.3)298 (78.7)4788×1895×244088849080
P1500-1400/230 V, 50 Hz1350108015001200Perkins4012-46TWG3ALeroy SomerLL8224L279.2 (73.8)313.4 (82.8)4888×1895×245592479448
480/277V, 60 Hz1350108015001200Perkins4012-46TWG3ALeroy SomerLL8224L289 (76.3)324 (85.6)4888×1895×245592479448
P1650-1400/230 V, 50 Hz1500120016501320Perkins4012-46TAG2ALeroy SomerLL8224N296.6 (78.4)326.3 (86.2)5044×2200×24611018110388
P1875-1400/230 V, 50 Hz1700136018751500Perkins4012-46TAG3ALeroy SomerLL9324F349.7 (92.4)390.2 (103.1)5259×2192×24531099711207
P2000-3400/230 V, 50 Hz1850148020001600Perkins4016-61TRG1Leroy SomerLL9324F383.8 (101.4)409.1 (108.1)5839×2196×26051221512528
P2250-3400/230 V, 50 Hz2000160022501800Perkins4016-61TRG2Leroy SomerLL9324H418.1 (110.5)470.8 (124.4)5839×2196×26051221512528
P2500-3400/230 V, 50 Hz2250180025002000Perkins4016-61TRG3Leroy SomerLL9324P470.6 (124.3)528.4 (139.6)6038×2184×29001298013380
 
Documentation
Operation and maintenance manual including circuit wiring diagrams.
 
Generator Set Standards
The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22.
 
Warranty
6.8 - 750 kVA electric power generation products in prime applications the warranty period is 12 months from date of start-up, unlimited hours (8760). For standby
applications the warranty period is 24 months from date of start-up, limited to 500 hours per year.
730 - 2500 kVA electric power generation products in prime applications the warranty period is 12 months from date of start-up, unlimited hours (8760 hours) or 24
months from date of start-up, limited to 6000 hours. For standby applications the warranty period is 36 months from date of start-up, limited to 500 hours per year.



Description of after-sales service system

Our company has nearly 10 years of on-site service experience. In the past 10 years, we have continuously equipped service engineers to provide various services for customers at home and abroad. For this project, according to our overseas service system and actual service requirements, we have adopted a comprehensive after-sales service plan, as follows:

1. After sales service responsible agencies: self operated, agent, including the generator set itself and supporting equipment, such as transformers.

Our company will specially arrange staff with the service ability of generator sets and supporting equipment (such as transformers, high and low voltage distribution cabinets) to provide on-site services and establish after-sales service organizations. During the service life of the equipment, our service engineers will ensure the safe and reliable operation of the equipment.

2. Response time for after-sales service requirements

During the service life of the equipment, our company is equipped with special personnel for on-site service, which can provide service response at any time.

3. Spare parts and after-sales service personnel

During the service life of the equipment, our company will provide 2000 operating hours of spare parts and 5000 operating hours of spare parts. During the installation and commissioning period, we will provide 2-3 after-sales service personnel on the site, at least 1 after-sales service personnel during the operation period, and at least 5 after-sales service personnel in the Egyptian branch to provide on-site support at any time.

4. Other details to be explained.

While producing and manufacturing high-quality products, our company also provides users with professional and personalized services. It has perfect domestic and overseas three-tier service institutions, rich service work experience and highly specialized technical service personnel who have been strictly trained to provide high-quality and perfect repair and maintenance services throughout the product life cycle.

Service commitment: professional, timely, efficient and high-quality

 
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA