extriCARE™ 2400 Specifications | |
Weight | 8.6 oz. |
Mobility | Portable, Carrying pouch included |
Battery Type | Lithium (rechargeable) |
Vacuum Modes | Continuous or intermittent |
Dimensions | Length: 3.35" (8.5 cm) |
Height: 5.67" (14.4 cm) | |
Width: 1.46" (3.7 cm) | |
Input | 100-240 V |
50/60 Hz | |
0.4 A |
extriCARE™ 2400 Operating Conditions | |
Temperature | +5ºC - 40ºC |
Humidity | 15% - 85% non-condensing |
Pressure Options | 60mmHg - 140mmHg |
Fuse | 1.5 A |
Charging Time | < 3.5 hours |
Barometric Pressure Range | 800 hPA - 1060 hPA |
Storage Temperature | -10°C - +45°C |
Altitude Range | < 2000 m |
Ingress Protection | IPX0 |
Protection Against Electric Shock | CLASS II |
Patient Protection | Type B |
extriCARE™ 3600 Device Specifications | |
Weight | 2.87 lbs (1.3 kg) |
Mobility | Portable |
Battery Type | Lithium (rechargeable) |
Vacuum Modes | Continuous or intermittent |
Dimensions | Length: 6.7" (17cm) |
Depth: 4.3" (11cm) | |
Height: 5.1" (13cm) | |
Input | 100-240 V |
50/60 Hz | |
1.5 A |
extriCARE™ 3600 Operating Conditions | |
Temperature | +5ºC - 40ºC |
Humidity | 15% - 93% |
Pressure Options | 40mmHg - 200mmHg |
Charging Time | < 5 hours |
Barometric Pressure Range | 800 hPA - 1060 hPA |
Storage Temperature | -25°C - +70°C |
Altitude Range | < 2000 m |
Ingress Protection | IP21 |
Protection Against Electric Shock | CLASS II |
Patient Protection | Type BF |
100P-30A Aspirator | Product Name | Code | Specification | Note | ||||||
100P-30A Aspirator | / | 100P-30A | / | |||||||
Wound Dressing PVA III | Product Name | Code | Specification/cm | Note | ||||||
Wound Dressing PVA III PVA III | 012131510 | 15×10×1 | / | |||||||
012132011 | 20×10×1 | |||||||||
012131505 | 15×5×1 | |||||||||
Wound Dressing PVA V | Product Name | Code | Specification/cm | Note | ||||||
Wound Dressing PVA V PVA V | 012151505 | 15×5×1 | / | |||||||
012151510 | 15×10×1 | |||||||||
Wound Dressing PU IV | Product Name | Code | Specification/cm | Note | ||||||
Wound Dressing PU IV PU IV | 012141510 | 15×10×3 | / | |||||||
012142010 | 20×10×3 | |||||||||
Film | Product Name | Code | Specification/cm | Note | ||||||
Film | 012150008 | 20×30 | / | |||||||
012150009 | 20×15 | / | ||||||||
Resuable Container | Product Name | Code | Specification/cm | Note | ||||||
Resuable Container | 010301000 | 1000ml | / | |||||||
Disposable Container | Product Name | Code | Specification/cm | Note | ||||||
Disposable Container | 010300110 | 110ml | / | |||||||
010300300 | 300ml | / |
Indications
-Open fracture
-Kinds of skin and soft tissue defect
-Bone exposure, tendon exposure
-Skin avulsion injury, skin degolving injury
-Osterofascial compartment syndrome
-Chronic osteromyelities
-Wound bed preparation for kinds of tissue flap transplantation operation
-Skin-grafting and protection for it's area
-Crush syndrome
-Fireman burn wound, acute burn wound
-Early burn wound, acute burn wound
-Electric burn wound, chemical burn wound, thermal burn wound
-Chronic skin ulcer, kinds of pressure ulcers diabetic foot etc
Contraindications
-Patients with Coagulation Disorders or blood diseases
-Patients with serious hypoproteinemai
-Cancer Ulcer Wound
-Active Bleeding Wound
-Other clinical patients not suitable for vacuum sealing drainage dressing
-Patients with serious biabetes
Negative Pressure Wound Therapy is an innovation treatment for surgical trauma.At present, it is the most advanced treatment for kinds of acute trauma and chronic skin ulcer. To fix wound dressing and drainage. Tube on clean wound and seal it by Biological Micro-porous Film. And then to connect the tube to a Vacuum Device, which can create regular and interval negative press to the wound.