Xmtg-608 Cj Intelligence Dual Row 3-LED Display Temperature Controller

Price $18.80 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 202 people viewed
Quantity
+-
 

Yuyao Gongyi Meter Co., Ltd.

VIP   Audited Supplier 15 years
Profile Certified by SGS/BV
XMTG-608
Customized
RoHS, ISO9001, CE, ISO
Cj
LED
48*48
Digital
Temperature Controller
Electronic Type
Temperature Control
CJ
1PCS/Box
ISO 9001: 2008 Others
China
9032900090
Product Description
Specifications

Temperature controller
On/off
PID control
Temperature meter are dual row 3-LED display
Input: CU50; PT100; J; E; K; T

XMT*608 series intelligent temperature controller, is double row 3-LED display and include on/off, PID control, including with parameter of self-setting function. This temperature meter respectively display temperature measurement value (PV) and temperature set value (SV) under normal mode; When it is time temperature control, respectively display temperature measurement value (PV) and running time count down (SV), and also provide kinds of time control method selection; The controller can input kinds of signal which are used interchangeably, it adopt ON/OFFP=0PID control, allowing an easy parameter setting and convenient inputting, is widely used over temperature automatic control systems of machinerychemicalceramicslight industrialmetallurgypetrifaction and heat treatment and so on.

 Main Technical Indexs
1. Measurement deviation: Class±0.5F.S±1, additional cold end compensation deviation±1°C
2. Input signal: CU50; PT100; K; E; J; T (one meter can be compatible)
3. Relay output contact capacity: AC240V 7A (resistance load)
4. Sampling period: 0.5s
5. Driving solid relay signal output: driving electric current> 15mA voltage>12V, period is 2S
6. Power: AC85-242V , 50HZ7.
7. Work environment: temperature 0-50.0°C, relative humidity≤85%RH, without corrode and strong electric radiation
 
 Model sense
               XMT(   )-6   (   )    8    (  )
                      1         2    3    4       5
1:External size and Installation hole(mm)
Empty   160×80×90   152×76         A   96×96×90   92×92
D   72×72×90    68×68         E   48×96×90   44×92
F   96×48×90   92×44         G    48×48×100   44×44
S   80×160×90   76×152      B    60×120×90   56×116
C   80×120×35  wall set installation
2. Operation display method:'6': 3-key gentel push-switch setting, double row digital display, have PID adjustment
3. An additional alarm:
Blank or '0': indicates no alarm;'1': High limit touch alarm;'2': low limit touch alarm
4. Input signal classification: '8' : Input signal can interchange free
5. Suffix:  None: relay output          G: solid state relay output
 

Code setting sheet
 
SeriesCodeNameSetting rangeRemarkEx-Factory
 
 
 
 
 
First 
 
 
 
 
 
 
 
 
 
Menu
 
 
0
 
-
Appointed dataDetermined
by
and 
Press∧or∨for 3 second and set the temperature setting value  you need  
-
 
1
 AL
 
High/Low-limit 
alarm
Determined
by
and 
 
-
 
Random
2SCMeasurement
deviation
-20.0~20.0Measuring value can be modified through increasing or decreasing this data.0
 
3
 P
 
 
Proportion time
0~99.9~200When the P↑,the proportion and differential
function↓;If the P↓,the proportion and 
differential function↑
When P=0,the meter is ON/OFF control.
15.0
 
4
 I
 
 
Calculus time
0~999It's used to adjust static difference. To increse it,the static difference will be reduced, but if it is too high, the static difference will drift instability.240
5 dDifferential time0~200
 
30
 
6
 
 t
 
Control period 
 
2~120S
When it leaves factory, SSR is 2s;
Relay is 20s. 
When P=0, it makes no sense.
 
20
 
7
 
 Hy
Main control by drop in level 
0.1~50.0
 
It only controls at ON/OFF
 
1.0
 
8
 At
 
 
Parameter setting itself
 
/
OFF_shut itself function  ;
ON_open itself function
Select ' ON'only can adjust for one time,and then turn back to 'OFF '
 
 OFF
 
9
 Loc
 
Electronics
lock
 
0~50
 Loc=0 all the parameter can be revised 
 Loc=1 only the appointed data can be revised
 
0

 
 
 
 
Second 
 
 
 
 
 
 
 
Menu
 
10 LocElectronics
lock
0~50idem0
11 SnInput type-CU50\PT100\K\E\J(\T;K
 
12
 
 dIL
 
Set lower limit
 
 
dIL≤dIH
CU50(-50~150)\
PT100(-80~600)\
K(-30~999)\E(-30~700)\
J(-30~900)\T(199~400)
 
 
0
 
13
 
 dIH
 
Set upper limit
 
400
 
 
14
 
 PF
 
 
 
Filt modulus
 
 
0~50
It is the software filter constant of  measurement sampling.The constant ↑,the measurement antijamming capability↑,but the measurement speed  and system response time ↓ 
 
20
15 COLSystem function 
choice
 
ON/OFF
ON:positive control(cooling control)
OFF:reverse control(heating control)
 
 OFF
Message Type