Yb6-11/15/33/0.4kv 50-2000kVA American Type Prefabricated Box Substation Compact Transformer

Price Negotiable Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 309 people viewed
Quantity
+-
 

ZHEJIANG KANGCHUANG ELECTRIC CO.,LTD

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
YB6
Box Transformer
50/60Hz
12kv
630-1250A
400V
50-2000kVA
CNKC
Wooden Case
50-2000KVA
China
Product Description

Product Description
YB6 series substation is american type combined substation with function of high voltage control, protect, power transformation and distribution. Usually used in urban and rural power distribution system .The high voltage load switch and high voltage fuse of this product are installed in the oil of the transformer, with the two structure: in same case with the transformer and in different case with transformer.



Model Description


Product technical parameters and external dimensions




Product structure features

1.Compact structure with small volume, the volume is 1/3-1/5 of European style substation in same capacity. It reduces the floor space efficiently.
2.Whole sealing and full insulated structure ,no need insulation distance. This can protect personal safety
3.High voltage wiring can use both in looped network and terminal with high reliability and flexibility
4. The transformer is with excellent performance, low loss, low Noise, low temperature rise, high overload capacity, strong impact resistant ability and high anti-short circuit capacity.
5.Cable head with two type: 200A elbow connector and 600A "T" type fixed cable connector. Both can equiped with all insulated ZnO lightning conductor. 200A elbow connector can use with load plug and with the function of insulation switch




Environment condition
1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h.
2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M.
3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually.
4. Installation gradient not exceed 5.
5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components.
6. Any specific requirement, consult with manufactory.




Product details


Products real shot



A corner of the production workshop


Product packaging



Product application case

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA