ZXKC-HB Circuit Breaker Dynamic Characteristics Tester Analyzer

Price $8599.00 Compare
Min Order 1 Piece
Shipping From Hubei, China
Popularity 312 people viewed
Quantity
+-
 

Wuhan GDZX Power Equipment Co., Ltd.

VIP   Audited Supplier 9 years
Profile Certified by SGS/BV
ZXKC-HB
1 Year
0.01ms-20000ms
380X280X170mm
8.4" LED
-10~+50 centigrade, relative humidity: ≤90%
6000 groups on-site test results
output 35~265V continuous, current output: ≤20A
AC 220V ± 10%;50Hz ± 2%
GDZX
Carton
China
9026209000
Product Description
High voltage switch dynamic characteristics tester is specially developed and produced to test the dynamic characteristics of various high voltage switches, such as oil switches, vacuum switches and sulfur hexafluoride switches. It is equipped with 8.4 inch color display, windows system, friendly interface, touch panel, suitable for on-site work

Features:
1.   8.4"LED panel, windows operation system, humanized operation interface, visualized interface, touch screen, all these are handy for use.
2.     High-speed thermal printer is used for printing test data on site.
3.     Interior integrated operational power supply, without needing on-site secondary power supply, is convenient and easy to use on site. It provides the range adjustable power supply from DC20~265V with 20A of current. Randomly set the operation voltage values of breaking and closing coil, and conduct an low voltage operation test of breaker.
4.     Equip with liner sensors, rotation sensors, universal sensors and holders, and dedicated fixed multifunction connectors, which could be easy to mount.
5.     It is fit for all types about SF switch, GIS composite apparatus, vacuum switch, oil switch, produced in domestic or abroad. 
6.     Obtain overall data and graphs by one on-off action.
7.     Mainframe can store 6,000 groups of on-site test data (support external memory card), internal real time clock, easy to file.
8.     Equip with USB interface, which could save data directly in USB disk, and upload in computer to analyze and preserve.
9.     Simultaneously measure contacts in 12 channels, closing resistance in 6 channels.
10.   Generate standard envelop curves through the test data of switch testing from several instruments (2~10), then conduct analyses and comparisons, and switch vibration frequency analyses as well.
11.   Internal anti-jamming circuit could meet 500KV inner reliable use in transformer substation.

Technique Parameter:
1. Time measurement:
     12 channels  fixed opening (closing) time
     Opening (closing) inner-phase non-synchronism
     Opening (closing) phase-to-phase non-synchronism
     Opening (closing) bounces time (and times)
     Testing range: 0.01ms~20000ms. resolution:0.01ms
 2. velocity measurement :
     instant opening (instant closing) velocity
     Appointed time slot( stroke segment or angle segment) average velocity
3. velocity measurement range:
     1mm sensor 0.01~25.00m/s,
     0.1mm sensor 0.001~2.50m/s
     0.5 dgree angle sensor 1 cycle/ 0.5 degree
 4. stroke measurement:
     moving contact stroke (stroke)
     contact stroke (opening)
     overshoot stroke or retrace (over travel)
     three way liner sensor :50mm, resolution: 0.1mm
     360 wire sensor : 360 degree,resolution:0.5 degree
     Matching sensor: 300mm, 1000mm, acceleration sensor
5. Closing resister measurement:
     6 way  fixed separating (closing) time
     separating (closing) inner-phase asynchronism
     separating (closing) phase-to-phase non-synchronism
     closing (separating) bounce time (bounce times)
     closing resister time input
     Testing range: 0~1300Ω, resolution: 1Ω, error: 1%
6. current: maximum current output:20A
7. Instrument power supply : AC 220V ± 10%;50Hz ± 2%
8. DC power supply: voltage output: 35~265V continuous adjustment, current output: ≤ 20A(short time )
9. disconnecting switch measurement range
     (1). Voltage output: DC35~265V(adjustable)
     (2). Current output time: 0.01~20 s (settable)
     (3). Contact signal maximum acquisition time: 20s
     (4). Contact closing, opening time, three-phase asynchronism, bounce time and frequency measurable .
10. Dimension: 380x280x170mm
11. Operating environment: -10~+50 centigrade
12. relative humidity: ≤90%




Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA