Zhongan S100 Point Gas Detector for Leakage Concentration of Combustible Gas

Price $1000.00 Compare
Min Order 1 Set
Shipping From Chongqing, China
Popularity 467 people viewed
Quantity
+-
 

Chongqing Jiuxin Automation Technology Co., Ltd

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
JX-S100
Whole Life Technical Support
One Year
New
Customized
Electrical Signal
Catalysis; Electrochemistry; S
Combustible Gas; Liquid Vapor Tvoc;
Natural Diffusion
(0~100%)Lel; 0-****Ppm
1%Lel; 1ppm/0.1ppm
Full Scale ±3%Lel
LCD Indication
Controller
<15s
<30s
<95%
Flameproof Type
IP65
G1/2
86kpa~106kpa;
J&X
Wooden Case
1500g
China
9027100090
Product Description

Zhongan S100 point gas detector


 
Brief description: 
Zhongan S100 point gas detector can meet the sound and light alarm prompts of gas detection site, and display and monitor the gas concentration in real time. The on-site debugging adopts infrared remote control, and the parameters can be set without opening the cover.
Zhongan S100 point gas detector is developed according to national standards and national quality technical requirements. This instrument can meet the sound and light alarm prompts of gas detection site, and display and monitor the gas concentration on site in real time. The on-site debugging adopts infrared remote control, and the parameters can be set without opening the cover.
Zhongan S100 point gas detector can convert the concentration signal of leaked gas in the air into electrical signal for remote transmission. The instrument can adopt two-wire RS3082, three-wire 4~20mA or four-bus RS485 output mode, which has the advantages of long transmission distance and anti-interference.
Zhongan S100 point gas detector is widely used in industrial environment to detect the leakage concentration of combustible gas, toxic and harmful gas.


technical indicators:
Detection principlecatalysis; electrochemistry; semiconductor; infrared
Detection gascombustible gas; liquid vapor TVOC; toxic and harmful gas
Sampling methodnatural diffusion
Test range(0~100%)LEL; 0-****PPM
Resolution1%LEL; 1PPM/0.1PPM
Measurement errorFull scale ±3%LEL
Status indicationLCD indication
Debugging methodcontroller
Response time<15s
Recovery time<30s
Ambient temperature -40ºC~70ºC
Relative humidity<95%;
Explosion-proof methodFlameproof type
Explosion-proof gradeExd || C T6 Gb
Explosion-proof certificate numberCNEx16.2871
Protection levelIP65
Power supplyDC24V/36V ±10%
Output signal4~20mA or RS485
Power consumption≤3W
Installation gong patternG1/2
Cable used≥1.5mm2×3; ≥1.5mm2×4
Maximum distance between detector and host≤1500m;
Machine weight≤1500g;
Pressure limit86kPa~106kPa;
Use placeUse in dangerous places with explosive flammable gas level IIA~IIC and temperature group T1~T6