cUL Certificate Electric PVC Copper Wire Nmd90 14/2 12/2 14/3 12/3 Indoor Non-Metallic Solid Conductor with Ground Electrical Wire 300V Canada

Price $0.98 Compare
Min Order 20000 Meters
Shipping From Hebei, China
Popularity 235 people viewed
Quantity
+-
 

Hebei Huatong Wires & Cables Group Co., Ltd.

VIP   Audited Supplier 10 years
Profile Certified by SGS/BV
NMD90 Wire
Insulated
Stranded
Overhead
Copper
PVC
PVC
Round Wire
Household
CSA
Huatong
CSA 22.2 N0.48
PVC +Nylon
300V
Roll
Huatong
Soft Packing
NMD90
Hebei, China (Mainland)
8544492100
Product Description

cUL Certificate Electric PVC copper  wire Nmd90 14/2 12/2 14/3 12/3 Indoor Non-Metallic Solid Conductor with Ground electrical Wire 300V Canada



Applications:

NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.
The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation.
The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to applications.


Standards:
Type NMD90 cable complies with:
ASTM
CSA C22.2 No. 48 (non-metallic sheathed cable)
Canadian Electrical Code1

CONSTRUCTION:


NMD90 cables are available as two- or three-conductor cables with a bare grounding conductor. It is manufactured using annealed (soft) copper conductors-compressed standing for stranded conductors; a heat-resistant thermoplastic polyvinyl chloride (PVC) insulation and nylon jacket for the individual conductors with a PVC jacket for the overall construction.
Conductors are white, black and red (for 3 conductor cables). Cable jackets are colour coded by size for quick identification in the Table below:
JACKET COLOUR CODE - Typical Application Guide
•WHITE - General Residential Wiring
•RED - 2 Black and Red conductors - 208V-240V Circuits (no neutral)
•ORANGE - No. 10 AWG General Residential Wiring
•YELLOW - No. 12 AWG General Residential Wiring
•BLUE - No. 14 AWG - 2 black and white conductors - 120V Arc Fault Circuit Interupter Applications

NMD90 jackets which reduces the coefficient of friction, allowing cables to be installed without external
lubricants, resulting in reduced labour and materials costs.
 
Specification:


AWG OR 
KCMIL
STRANDNOMINAL INSULATION 
THICKNESS INCH/MM
NOMINAL JACKET 
THICKNESS INCH/MM
NOMINAL OVERALL 
DIAMETER INCH/MM
CABLE WEIGHT 
LBS/KFT KG/KM
1410.0150.380.0040.100.112.791522
1210.0150.380.0040.100.123.052334
1010.0200.510.0040.100.153.813754
14190.0150.380.0040.100.112.791624
12190.0150.380.0040.100.133.302436
10190.0200.510.0040.100.174.323958
8190.0300.760.0050.130.225.596394
6190.0300.760.0050.130.266.6098145
4190.0401.010.0060.150.338.38157234
3190.0401.010.0060.150.369.14193287
2190.0401.010.0060.150.399.91240357
1190.0501.270.0070.180.4310.92300446
1/0190.0501.270.0070.180.4711.94376560
2/0190.0501.270.0070.180.5213.21467695
3/0190.0501.270.0070.180.5714.48581864
4/0190.0501.270.0070.180.6416.267241077
250370.0601.520.0080.200.6917.538551272
300370.0601.520.0080.200.7619.3010221521
350370.0601.520.0080.200.7920.0711911772
400370.0601.520.0080.200.8521.5913452001
500370.0601.520.0080.200.9423.8816682482
600610.0701.780.0090.231.1027.9419942967
750610.0701.780.0090.231.1629.4624653668


 