for Various Ventilators and Oxygen Concentrators Oxygen Sensor O2 Sensor

Price $47.00 Compare
Min Order 1 pieces
Shipping From Ningxia, China
Popularity 371 people viewed
Quantity
+-
 

Ningxia Maiya Sensor Technology Development Co., Ltd

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
OOM202
Electrochemical Gas Sensor
Non-conductivity Type
Analog Type
Integration
Metal
High
CE
Non-Customized
0.5 to 35 Vol.%
~ 1,200,000 Vol.% H
≥ 1 000 000 % Volume Oxygen Hours
13 Mv ... 16 Mv
< 1 % Volume O2 at Constant Temperature and Pressu
< 12 S to 90 % of Final Value
0 °c ... +50 °c
0 % ... 99 % Rh Non-Condensing
< 30 Minutes, After Replacement of Sensor
28g
ENVITEC
Cartons
Germany
9027100090
Product Description
Product Description

The EnviteC OOM202 Oxygen Sensor is a highly accurate and reliable sensor designed for use in medical applications where precise oxygen concentration measurements are required. This sensor is particularly suitable for oxygen analyzers, offering exceptional performance in a wide range of devices, including oxygen concentrators, medical ventilators, anesthesia equipment, and incubators.

Manufactured in Germany, the OOM202 sensor adheres to stringent industry standards, including ISO 80601-2-55 and EN ISO 13485, ensuring high quality and reliability. It is compliant with European MDD (CE certified) and has been cleared by the FDA, making it a trusted choice for medical professionals worldwide.

Key features of the OOM202 Oxygen Sensor include:

  • Wide measurement range: It accurately measures oxygen levels from 0% to 100% at atmospheric pressure.
  • Fast response time: The sensor reaches 90% of its final value in under 12 seconds, ensuring rapid feedback in dynamic environments.
  • Long sensor life: With a nominal lifetime of over 1,000,000 hours of oxygen exposure, the OOM202 is designed for long-term, reliable use.
  • Built-in temperature compensation: An integrated NTC compensation system minimizes the influence of temperature variations, ensuring stable performance across a wide temperature range (0°C to +50°C).
  • Low maintenance: The sensor exhibits a low long-term output drift, typically less than 1% oxygen volume per month, reducing the need for frequent recalibration.
  • Excellent resistance: The sensor is resistant to Nitrous Oxide (N2O) and other environmental influences such as humidity and mechanical shock, making it suitable for various medical and industrial environments.

The OOM202 sensor is designed to be integrated easily into existing oxygen monitoring systems. Its 3-pin electrical interface (Molex® 22-11-1031) ensures compatibility with most systems. Additionally, the sensor offers high stability, excellent signal quality, and a broad operational range, making it an ideal choice for system monitoring in medical applications.

For further customization, EnviteC's engineering team can work with clients to design sensors tailored to specific requirements, such as varying signal levels or the addition of extra temperature compensation elements.

This sensor is available through EnviteC's website, and detailed product documentation, including instructions for use and the EnviteC XRL Cross Reference List, can be downloaded for easy integration into any system.

Made in Germany and supported by a globally recognized company, the OOM202 Oxygen Sensor is a reliable and high-quality solution for precise oxygen measurement in critical medical applications.
 

ParameterSpecification
Measurement Range0% to 100% oxygen (at atmospheric pressure)
Nominal Sensor Lifetime≥ 1,000,000 % volume oxygen hours
Output in Ambient Air13 mV to 16 mV
Electrical Interface3-pin (Molex® 22-11-1031)
AccuracyMeets ISO 80601-2-55 requirements
Repeatability< 1% volume O2at constant temperature and pressure
Linearity Error< 3% relative
Response Time< 12 seconds to 90% of final value
Zero Offset Voltage< 200 μV in 100% nitrogen, applied for 5 minutes
Cross InterferenceMeets ISO 80601-2-55 requirements
Humidity Influence-0.03% relative per % RH at 25°C
Pressure Range0.6 bar to 2 bar (ppO2 0 to 1250 mbar O2)
Pressure InfluenceProportional to change in oxygen partial pressure
Mechanical Shock Influence< 1% relative after a fall from 1 meter
Operating Temperature0°C to +50°C
Temperature CompensationBuilt-in NTC compensation
Effect of Temperature Compensation3% relative error between +25°C and +40°C; 8% relative error between 0°C and +50°C
Operating Humidity0% to 99% RH (non-condensing)
Long-Term Output Drift< 1% volume oxygen per month, typically < -15% relative over lifetime
Storage Temperature-20°C to +50°C
Recommended Storage Temperature+5°C to +15°C
Recommended Load≥ 10 kOhms
Warm-up Time< 30 minutes after sensor replacement
WeightApproximately 28 grams
Part Number01-00-0047

 

Company Information

Packaging & Shipping

 

FAQ

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA