pH Calibration Buffer Solution Powder for pH Meter Measure Calibration

Price $0.90 Compare
Min Order 10 Sets
Shipping From Henan, China
Popularity 309 people viewed
Quantity
+-
 

Zhengzhou Wollen Instrument Equipment Co., Ltd.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
Portable
Food Analysis, Medical Research, Biochemistry
ISO9001, CE
pH Buffer Powder
Bagged Powder
About 3G Each Bag
4.01, 6.86 and 9.18
250ml Standard Solution Per Bag
Two Years
WollenLab
Carton Box
3g/bag
China
2835299000
Product Description
pH Calibration Buffer Solution Powder for pH Meter Measure Calibration


Applications:

The PH buffer powder/calibration powder is used to calibrate the accuracy of the electronic PH measurement probe. The electronic PH measurement probe has high accuracy, but the test results will shift with long-term use. Therefore, the measurement probe should be calibrated regularly during use.


Product Parameters:

 
Name of CommodityPH Buffer Powder/Calibration Powder
Product StandardBagged powder
WeightAbout 3g each bag
PH Value4.01, 6.86 and 9.18
Proportion250ML standard solution per bag
Expiration DateTwo years
Preservation MethodUnopenedKeep in a ventilated and cool place and avoid sunlight.
After openingAt a low temperature of 4~16C, use it within 3~6 months.
 
 
How to calibrate?
 
1. Wash the electrode of the pH meter with pure water (2-3 times), then immerse the electrode in the calibration solution, and adjust the pH value of the pH meter to same as the value of calibration solution.
2. If you want the instrument to be more accurate, you can use two-point or three-point calibration. The so-called two-point calibration is to calibrate with two specifications of calibration fluid, and the three-point calibration is to calibrate with three specifications of calibration fluid.
3. Generally start calibration from 6.86 first, and then use 4.01 or 9.18.
4. After the first calibration, you should gently wipe off the liquid on the electrode with a paper towel, and then perform the next step of calibration to avoid contamination of the calibration solution, thereby greatly improving the shelf life of the solution.

Correction Frequency of PH Meter:
 
1. The pH meter is always in the working state, that is, it monitors the PH value for a long time, and it should be corrected once a week to ensure accuracy. The calibration is needed only about 3 months for normal frequency use.
2. The test pen is used to detect PH from time to time and should be calibrated before testing to ensure accuracy.
                                                                   

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA