Profile Certified by SGS/BV
VTJ4340A 12kv 400a/630a 10ka
High Voltage Circuit Breakers
Electric Type
Normal Type Circuit Breaker
Vacuum
Fixed
Contactor
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), MV
ISO9001-2000
Feite Brand
Cartons/Pallets
China
8535900090
Product Description
Vacuum interrupter for contactor
VTJ4340A
ZKTJ 400/12-6.3
ZKTJ 630/12-6.3


 

Vacuum Interrupter for Contactor

Vacuum arc extinguishing chamber, also known as vacuum switch tube, is the core component of the high voltage power switch, its main role is to cut off the arc and inhibit the electric current by its high inside insulation performance to avoid accidents.

Wuhan Feite Electric brand vacuum arc extinguishing chamber adopts a corrugated ceramic insulation shell, copper tungsten tungsten carbide alloy materials contact, using advanced one exhuast technology process makes the vacuum interrupter has the advantages of small volume, high insulating level, low closure value, long service lifetime, easy-maintenance, explosion-free, low noise, low maintenance costs, reliable operation and non-pollution etc.. The vacuum arc extinguishing chamber mainly been used in power transmission and distribution control system. It is also can be used in metallurgy, mine, petroleum, chemical industry, railway, broadcasting, communications, industrial high frequency heating power distribution system.

Wuhan Feite Electric vacuum arc extinguishing chamber for vacuum contactor rated voltage is 1.14~40.5kV, rated current is 630A~1250A


Main Technical Data 
ELECTRICAL RATINGS(3PHASE) SYMMETRICAL BASIS 
1.Rated Voltage12KV
2.Rated Current400/630A
3.Rated Frequency50Hz 
4.Rated Short-time Power Frequency Withstand Voltage(1min) 70KV
5.Rated Lighting Impulse Withstand Voltage107KV
6.Rated Making Current6.3KA
7.Rated Breaking Current,Max5.0KA
8.Rated Breaking Current,Min125A
9.Rated Making Current,Limit6.3KA
10.Rated Short-time Withstand current6.3KA
11.Rated Duration of Short-circuit4s
12.Mechanical Life30×times
13.Electricity Life AC-325×times
14.Electricity Life AC-410×times
15.Rated Contactl Stroke8±1mm
16.Contact Closing Force Due to bellows and atmosphere120±50N
17.Counterforce at rated contact stroke190±60N
18.Circuit resistance at rated contact atmosphere force≤45 µ
19. Shelf life20years
20.Contact erosion limit3mm
21.Weight of moving parts≤1.2kg
MECHANICAL REQUIREMENTS(REF. VCB) 
1.Added contact force500±50N 
2.Average opening speed1.0±0.2m/Sec 
3.Average closing speed0.6±0.2m/Sec 
4.Contact Bouncing Duration at closing operation≤2ms
5.Contact Bouncing Bank Amplitude of Opeing Operation≤2mm 
6.Three-pole simultaneity≤1ms
Notes:
1.Meets or exceeds the electrical endurance requirements of class E2 for autoreclosing duty per IEC 62271-100 and GB 8738-2008.
2.* Rated Characteristics to be given on request
 