H-100
±0.6-1%
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Tube/Flange
Variable Area Flow Meter
Mechanics
DIN, GB, CE
Dn15---Dn300
4-20mA
Hart
Beifang
Carton
ISO
China
Product Description
Variable area flowmeter

Range: DN15---DN300
Measure Liquid, gas, vapor
Flange: DIN, ANSI, HG, GB; Thread
Temperature: -80C---300C

Variable area flowmeter
Special features

1. Rugged all-metal design
2. Easy stocking of parts thanks to modular concept
3. Complete interchangeability of all components and assemblies
4. Linear display
5. Adjustable to any fluid through replaceable cam plate
6. Shot-stroke design/parts do not project beyond the flanges, no matter what position the float is in
7. Electrical or pneumatic remote data transmission system
8. Limit switches can be installed

Operating data
Max pressure:
DN15~DN50 PN4.0MPa (Special versio 25MPa)
DN80~DN100 PN1.6MPa (Special versio 16MPa)
Temperature of fluid: -80 deg C~+220 deg; C
Current output: 4-20mA (Optional)
Electaic: M20*1.5, PG11, 1/2"NPT
ItemVariable area flowmeter
Metering range(100% values) Water (20° C)                                      6~15000 l/h
Air  (0.1013MPa 20° C)                      0.05~4000 m 3 /h
Rangeability10: 1
Accuracy class   1.5 (Special version 1.0)
  Operating data
 
Max pressure DN15~DN50  PN4.0MPa (Special versio 25MPa)
DN80~DN100 PN1.6MPa (Special versio 16MPa)
Temperature of fluid -80° C~+220° C 
Ambient temperature Max 120° C(Max. 60° C if signal output is electrical)
Current output4-20mA (Optional)
Viscosity of fluid DN15: ≤ 5mPa. s(H15.1~H15.3)
                          ≤ 30mPa. s(H15.4~H15.9)
DN25: ≤ 250mPa. s         
DN50~DN150: ≤ 300mPa. s 
Connection    Standard Flange to DIN2501 or ANSI  , Special    Other standards on request
Electaic   M20× 1.5, PG11, 1/2" NPT
Owerall height 250mm
Protection category to DIN 40050IP65
Explosion ProofExiaIICT3~6
ExdIIBT4