Login| Register| Forgot Password| Admin Panel Home| Mobile| Cart
VIP   Audited Supplier8 Years

Jinan Amrta Air Conditioning Co., Ltd.  

Chiller, Air Cooled Water Chiller, Rooftop Packaged Unit, Tent Package Unit, Water Cooled Water Chiller, Glycol/Brewage/Dairy Water Chiller, Heat Pump, Central Air Conditioning, Air Source Heat Pump, Fan Coil Unit

Search
Categories
Search
 
MadeInChina.com > Jinan Amrta Air Conditioning Co., Ltd. > Product > Vrf Hi-Flexi S Mavo Series Cooling Only DC Inverter Air Conditioning System
Product

Vrf Hi-Flexi S Mavo Series Cooling Only DC Inverter Air Conditioning System

价格 $6500.00对比
发货 Shandong
销量 暂无
评价 已有 0 条评价
人气 已有 269 人关注
数量
+-
库存5Piece   起订1Piece
IP UnknownLearn More
AVWT-
Central Air Conditioners
8HP~112HP
Room
<23dB
CE, CCC, RoHS, CECC, GS, MEPS, UR, BEB
Level 1
Cooling/Heating
Electrical
DC
New
380~415V-50/60Hz
Hisense
Carton Package with Wooden Box
China
Product Description

 

Hisense Brand Hi-FLEXi S mavo Series
Cooling Only

S mavo series cooling only unit is based on the latest product platform. Capacity range and EER have been improved greatly compared with the previous product.
 

Enhanced EER

Through the optimization and upgrading of key components such as compressor and heat exchanger, as well as the state-of-the-art technologies application, the overall energy efficiency of S mavo series cooling only unit has been increased by up to 10%. What's more, a new high-efficiency lineup is available through optimized module combination, ensuring a higher efficiency operation.

Patented 360° Fitted Refrigerant Cooling Technology

To maintain the lifespan of the delicate electronics, Hi-FLEXi S mavo series cooling only unit uses a patented 360 degree fitted refrigerant cooling technology, to effectively cool the whole electronic box. It overcomes poor heat dissipation and solves high ambient temperature issues inside the electronic box, to maintain an efficient and reliable operation under harsh environment. What's more, the refrigerant cooling unit adds a temperature sensor, which could be more precise to control the refrigerant cooling temperature and enhance the whole reliability.

 

Triple Backup Operation

Module Backup Operation

If one module in a combination system malfunctions, the other ones can still keep working to ensure an emergency operation until service and repair.

 

Compressor Backup Operation

In the single module system equipped with two compressors, if one compressor malfunctions, the other one can provide emergency operation. In the combined modules, if the compressor in one module goes wrong, the other modules can provide emergency operation. Thus a stable and continuous operation can be ensured thanks to the backup of compressors.



 

Fan Backup Operation

For the module equipped with two fans, if one fan breaks down, the other one won't be inflfluenced, the module can still keep working.

 


Max. 200% of Connection Ratio

The max. connection ratio between indoor units and outdoor units in the single module system can reach 200%, which can improve the flflexibility of design largely and reduce the cost of projects whose air condition systems always work under partial load considerably. For double modules, triple modules and four module combined units, the max. connection ratios are 180%, 160%, 150% respectively.


Hi-FLEXi S mavo Series Cooling OnlyLineup