Login| Register| Forgot Password| Admin Panel Home| Mobile| Cart
VIP   Audited Supplier3 Years

Shanghai Huakun Electrical Company Ltd.  

Active Harmonic Filter, Static Var Generator, Capacitor, MCCB

Search
Categories
Search
 
MadeInChina.com > Shanghai Huakun Electrical Company Ltd. > Product > Thdi5% Static Var Generator 3p3w Static Var Generator
Product

Thdi5% Static Var Generator 3p3w Static Var Generator

价格 $1500.00对比
发货 Shanghai
销量 暂无
评价 已有 0 条评价
人气 已有 245 人关注
数量
+-
库存5Piece   起订1Piece
IP UnknownLearn More
SVG045
Distribution Metering Box
Fixed Board
ISO9001:2000, CCC, CE
All- packaged Type
Low Voltage
486*88*504 mm
Power Factor Correction
Aluminum-Zinc Coated Case
IP30
Huakun
Wall Mounted/Rack Mounted
3p3w/3p4w
<65dB
2~50th Harmonic Order
> 97%
Harmonic Correciton, Reactive Var Compensation
Huakun
Wooden Box
682*567*277cm
Shanghai, China
8543709990
Product Description
Static Var Generator (SVG) is a product aimed for Power Factor Correction, Voltage Regulation along with Three-phase Balancing Function. SHHKK-SVG can do bi-directional power factor correction, PF from 1.0 inductive to 1.0 capacitive. Benefiting from inverter technology, SVG compensation is stepless, which means SVG output shall match the system reactive power, no over-compensation or under compensation. For single module, SVG capacity ranges from 35kvar to 150kvar. For cabinet system, it's unlimited parallel design .
Compared with the traditional capacitor bank, SVG has the advantages of fast response and high
compensation accuracy without under-compensation or over-compensation problems.
Δ  Improved power factor PF ≥ 0.99
Δ  Compensated inductive or capacitive reactive
Δ  Unaffected by harmonics

HKK-SVG static var generator is a bridge converter composed of fully controlled power electronic devices for dynamic reactive compensation. The basic principle is that the load current is detected in real time by the external current transformer (CT), and the reactive content of load current is extracted by the internal DSP computing. Finally, the instruction value is calculated to control the PWM signal generator to send the control signal to the internal IGBT, so that the inverter can produce the reactive compensation current to meet the requirement, and finally realize the dynamic reactive compensation.


System parameters
Rated input wire voltage
3 8 0 V(-1 5%~+2 0%)
Grid frequency
5 0 / 6 0 H z ( r a n g e : 4 5 H z~6 2 H z)
Number of parallel machines
1 ~ 1 0 s e t s
Overall efficiency
≥9 7%
Grid structure
T h r e e - p h a s e t h r e e - w i r e / t h r e e - p h a s e f o u r - w i r e
Current transformer
1 5 0/5~1 0 0 0 0/5
Circuit topology
T r i - l e v e l
 P e r f o r m a n c e   i n d e x
Response time
<1 5 m s
Scope of compensation
F r o m - 1 t o 1 , c a p a c i t i v e  a n d  i n d u c t i v e  c o n t i n u i t y  i s  a d j u s t a b l e
Cooling mode
I n t e l l i g e n t   a i r   c o o l i n g
Noise index
<5 6 d B