Low Volage Overhead Network UTP Cat5e Cable
Product Description
Category 5E (Cat 5E) is a twisted pair cable for carrying signals. This type of cable is main used in structured cabling
for computer networks such as Ethernet, supports a frequencyrange of up to 100MHz and is designed for transmission
speeds of up to 1 gigabit per second(Gigabit Ethernet). It is also used to carry other signals
such as telephony and video.
cat5e utp Constructions:
Conductor AWG:24awg,26awg,28awg
Conductor Material:CCA,CCA+CCS,BU(Bare Copper)
Insulation:high density polyethylene(HDPE)
Twisting:8 twisted pairs, 2 single conductors paired,
Jacket: PVC/PE/LSZH(Low Smoke Zero Halogen)
Temperature Range: 0° to +70°C
Specification and Electrical Characteristics
Company Information





Product Description
Category 5E (Cat 5E) is a twisted pair cable for carrying signals. This type of cable is main used in structured cabling
for computer networks such as Ethernet, supports a frequencyrange of up to 100MHz and is designed for transmission
speeds of up to 1 gigabit per second(Gigabit Ethernet). It is also used to carry other signals
such as telephony and video.
cat5e utp Constructions:
Conductor AWG:24awg,26awg,28awg
Conductor Material:CCA,CCA+CCS,BU(Bare Copper)
Insulation:high density polyethylene(HDPE)
Twisting:8 twisted pairs, 2 single conductors paired,
Jacket: PVC/PE/LSZH(Low Smoke Zero Halogen)
Temperature Range: 0° to +70°C
Specification and Electrical Characteristics
Conductor | Thick.of insulation mm | Nominal O.D. mm | Weight kgs/305m box | ||||||||
24AWG | 0.91±0.005 | 5.0±0.2 | 9.0 | ||||||||
Max. Conductor Resistance: 9.2Ω/100m | Min. Insulation Elongation: 300% | ||||||||||
Max. Resistance Unbalance: 2.4% | Min. Propagation Velocity: 0.62C m/s | ||||||||||
Min. Conductor Elongation: 20% | Characteristic Impedance: 100±15Ω | ||||||||||
Min. Insulation Resistance: 7000MΩ/km | |||||||||||
Frequency (Mhz) | Insertion Loss (Soild) Max,dB/100m | Next (Worst pair to pair) Min.dB | PSNEXT Power Sum NEXT Min.dB | ELFEXT Power Sum ELFEXT Min.dB/100m | PSLFEXT Power Sum ELFEXT Min.dB/100m | Return Loss Min.dB | |||||
1 | 2 | 65.3 | 62.3 | 20 | 64 | 61 | |||||
10 | 6.5 | 50.3 | 47.3 | 25 | 44 | 41 | |||||
25 | 10.4 | 44.3 | 41,3 | 24.3 | 35.8 | 33 | |||||
31.25 | 11.7 | 42.9 | 39.9 | 23.6 | 34.1 | 31.1 | |||||
62.5 | 17 | 38.4 | 35.4 | 21.5 | 28.1 | 25.1 | |||||
100 | 22 | 35.3 | 32.3 | 20.1 | 24 | 21 |